Laserfiche WebLink
3.2 Laboratory Testing <br /> Laboratory tests for natural moisture content (ASTM Standard D2216) and percent passing a No. 200 <br /> sieve (ASTM Standard DI140) were completed on selected samples from the SPT borings. The test data are <br /> summarized below in Table 1. Laboratory test reports are included in Appendix C. <br /> Table 1 <br /> Laboratory Test Results <br /> Barker Residence <br /> -Sam }fie Stra�am } % Moisture . ° ° QO <br /> Content Sieve <br /> SPT -1, 4 to 6 ft. 2 6.5 16.8 <br /> SPT -1, 6 to 8 ft. 2 11.4 25.5 <br /> SPT -1, 8 to 10 ft. 2 10.6 25.3 <br /> SPT -1, 13'Y2 to 15 ft. 2 55.8 76.6 <br /> SPT -2, 4 to 6 ft. 2 8.5 18.3 <br /> SPT -2, 6 to 8 ft. 2 9.6 17.7 <br /> SPT -2, 8 to 10 ft. 2 8.9 16.9 <br /> SPT -2, 13'/2 to 15 ft. 2 48.1 80.6 <br /> SPT -3, 8 to 10 ft. 2 15.2 19.3 <br /> SPT -3, 13'/2 to 15 ft. 2 23.7 26.2 <br /> SPT -3, 18'h to 20 ft. 2 30.9 27.6 <br /> Notes: Borehole locations shown on Figure 2 <br /> Sample depths shown in feet below grade <br /> Subsidence Investigation BCI Project No.: 19 -17094 <br /> Barker Residence March 2009 <br /> Claim No.: 3428 Page 6 <br />