FORM 600A-2004R EnergyGauge® 4.5.2 <br /> Code Compliance Checklist <br /> Residential Whole Building Performance Method A - Details <br /> 1 ADDRESS: 505317 TH ST, Zephyrhills, FL, 33542- PERMIT #: I <br /> 6A -21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> COMPONENTS i SECTION I REQUIREMENTS FOR EACH PRACTICE I CHECK <br /> _ Exderior Windows & Doors 606.1.ABC.1.1 l Maximum:.3 cfm/sq.ft. window area; .5 cfm/sq.ft. door area. <br /> Exterior & Adjacent Walls 606.1.ABC.1.2.1 I Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> I foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility <br /> I (penetrations; between wall panels & top/bottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> 1 from, and is sealed to, the foundation to the top plate. <br /> Floors 606.1.ABC.1.2.2 i Penetrations/openings >l/8" sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> i to the perimeter, penetrations and seams. <br /> Ceilings 606.1.ABC.1.2.3 I Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> I soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate; <br /> I attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> I installed that is sealed at the perimeter, at penetrations and seams. <br /> Recessed Lighting Fixtures 606.1.ABC.1.2.4 (Type IC rated with no penetrations, sealed; or Type IC or non -1C rated, installed inside a <br /> t sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br /> cone io • _de i <br /> Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. <br /> Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combustion air, <br /> 6A -22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br /> COMPONENTS 1 SECTION I REQUIREMENTS l CHECK <br /> Water Heaters 1 612.1 I Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir <br /> I breaker electric or cutoff • - s must be • rovided. External or built-in heat trap required. <br /> Swimming Pools S, Spas j 612.1 , Spas & heated pools must have covers (except solar heated). Non - commercial pools 111 <br /> 4 must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> I ' efficency of 78%. <br /> Shower heads 1612.1 I Water flow must be restricted to no more than 2.5 gallons per minute at 80 PS1G. <br /> Air Distribution Systems 1610.1 I All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> I I attached, sealed, insulated, and installed in accordance with the criteria of Section 610. <br /> 1 i Ducts in unconditioned attics: R-6 min. insulation. <br /> HVAC Controls I 607.1 Separate readily accessible manual or automatic thermostat for each system. <br /> Insulation 1 604.1, 602.1 Ceilings -Min. R -19. Common walls -Frame R -11 or CBS R -3 both sides. <br /> Common oiling & floors R -11. <br /> I { <br /> EnergyGauge rm DCA Form 600A -2004R EnergyGauge®/FIaRES2004R FLRCPB v4.5.2 <br />