My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
09-9136
Zephyrhills
>
Building Department
>
Permits
>
2009
>
09-9136
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2011 11:40:17 AM
Creation date
1/13/2011 11:40:13 AM
Metadata
Fields
Template:
Building Department
Company Name
OAK RUN
Building Department - Doc Type
Permit
Permit #
09-9136
Building Department - Name
KIRKER,STEVEN
Address
7336 HIGHLAND LP
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M 1 A M IDADE MIAMI-DADE COUNTY, FLORIDA <br /> METRO -DADE FLAGLER BUILDING <br /> BUILDING CODE COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603 <br /> PRODUCT CONTROL DIVISION MIAMI, FLORIDA 33130 -1563 <br /> (305) 375 -2901 FAX (305) 375 -2908 <br /> NOTICE OF ACCEPTANCE (NOA) <br /> Simonton Windows <br /> One Cochrane Drive, <br /> Pennsboro, WV 26415 <br /> SCOPE: <br /> This NOA is being issued under the applicable rules and regulations governing the use of construction materials. <br /> The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted <br /> by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by <br /> the Authority Having Jurisdiction (AHJ). <br /> This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control <br /> Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to <br /> have this product or material tested for quality assurance purposes. If this product or material fails to perform in <br /> the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately <br /> revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right <br /> to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or <br /> material fails to meet the requirements of the applicable building code. <br /> This product is approved as described herein, and has been designed to comply with the Florida Building Code, <br /> including the High Velocity Hurricane Zone. <br /> DESCRIPTION: Series "5500" PVC Fixed Window <br /> APPROVAL DOCUMENT: Drawing No. S -2366, titled " Extruded Vinyl PVC Picture Window ", sheets 1 <br /> through 5of 5, prepared by R.W. Building Consultant Inc., dated 07 -14 -03 and last revised on 12- 09 -03, signed <br /> and sealed by Wendell W. Haney, P.E., bearing the Miami -Dade County Product Control Approval stamp with the <br /> Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division. <br /> MISSILE IMPACT RATING: None (Approved Shutter/External Protection device required) <br /> LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and <br /> following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. <br /> RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no <br /> change in the applicable building code negatively affecting the performance of this product. <br /> TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the <br /> materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any <br /> product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply <br /> with any section of this NOA shall be cause for termination and removal of NOA. <br /> ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by <br /> the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall <br /> be done in its entirety. <br /> INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors <br /> and shall be available for inspection at the job site at the request of the Building Official. <br /> This NOA consists of this page 1 and evidence page E -1, as well as, approval document mentioned above. <br /> The submitted documentation was reviewed by Ishaq I. Chanda, P.E. <br /> Q , r c , NOA No 03- 0811.03 <br /> Expiration Date: February 26, 2009 <br /> ° _ • Approval Date: February 26, 2004 <br /> A \ ye ti Page 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.