Laserfiche WebLink
05- 20 -'09 09: 00 FROM -ABC SUPPLY CO. 3525232227 T -850 P0081011 F -037 <br /> SY'SThM A 2S: "W" 26 Ga. Metal Panel <br /> Deck Type: Wood, Non - insulated <br /> Deck Description: 19 42" or greater plywood or wood plank. <br /> Slope Range: 2 ": 12" or greater <br /> Maximum Uplift The maximum allowable design pressure for the 24" wide panel <br /> Pressure: shall be 420.9 psf. (See General Limitation #1) <br /> Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less <br /> than #8 x 2" wood screws spaced 6" o.c around the perimeter and 12" o.c. in <br /> the field.. In reroofing, where the deck is less than 14 !32" thick (Minimum <br /> 15 /32') The above attachment method must be in addition to existing <br /> attachment. <br /> Underlayment: Minimum underlaytnent shall be a ASTM D 226 Type II installed with a <br /> minimum 4" side -laps and 6" end -laps. Underlayment shall be fastened with <br /> corrosion resistant tin -caps and 1A" annular ring -shank nails, spaced 6" o.c. <br /> at all laps and two staggered rows 12" o.c. in the field of the roll. <br /> Valleys: Valley construction shall be in compliance with Roofing Application <br /> Standard RAS 133 and with Union Corrugating Company's current published <br /> installation instructions. <br /> Fire Barrier Board: For class A or B fire rating, install minimum 1/4" thick Georgia Pacific "Dens <br /> Deck" (with current NOA) or minimum 4mm thick of Tritex, Rockiioof (with <br /> current NOA) or 5 /g" water resistant type X gypsum sheathing with treated <br /> core and facer or Elk Versashield (with current NOA). <br /> Metal Panels and Install. the "SV Steel Roofing Panel" and accessories in compliance with <br /> Accessories: Union Corrugating Company's current published installation instructions and <br /> details. Hashing, penetrations, valley construction and other details shall be <br /> constructed in compliance with the minimum requirements provided in <br /> Roofing Application Standards RAS 133. <br /> SV Roofing Panels shall be fastened with a minimum of #9 Hex Head Wood <br /> corrosion resistant fasteners with sealing washer. Fasteners shall of sufficient <br /> length to penetrate through the sheathing a minimum of 3 46 ". Fasteners shall <br /> be place in accordance with fastener detail herein as follows: <br /> 3. Panel side ribs shall be fastened along side of the panel inside ribs, one <br /> fastener at the overlap and one fastener at the underlap. Center panel rib <br /> shall be fastened with one fastener at the overlap side of the panel. <br /> 4. All fasteners at center rib, underlap rib, and overlap rib shall be spaced <br /> at a maximum of 24 inches o.c. parallel to the roof slope. See Detail B <br /> herein. <br /> NOA No.: 06- 1002.13 <br /> Expiration Date: 06/17/12 <br /> Approval Date: 06/14/07 <br /> Page 4of7 <br />