Laserfiche WebLink
APPENDIX 13 -D <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> SUBCHAPTER 4 - Commercial Building Compliance Methods <br /> Form 400C -04 Central <br /> Building Prescriptive Envelope Method Climate Zones 4 5 6 <br /> Project Name: nn� �11 Zone: <br /> Address: Cr, 15 3 it/ edr't;s1.. i t ;secs) Building Classification: <br /> CS , Zi. Code: 35 Z Buildin. Permit No.: ����,�� <br /> Builder: Qv tM0.� Permitting Office: -, - �� e1 <br /> Owner: Jurisdiction No.: le I GOOD <br /> BUILDING ENVELOPE INFORMATION <br /> ENVELOPE COMPONENT Nonresidential Residential Semiheated <br /> U1actor R -value 7 (Mentor R -value (- factor R - value <br /> Roof type: e 6 � 3 f 1 a' 7 <br /> Wall type: ar .7'Z' ^7 ' 4" Z <br /> Floor type: <br /> Fenestration Max. U Max. SHGC Max. U•(actor Max. SHGC Max. U- factor Max. SHGC <br /> • Fixed/operable All orientation Fixed /operable All orientation Fixed/operable All orientation <br /> Vertical glazing type, % of wall: $J' / y - 1 s le 2. -2- K y v • <br /> Skylight type, % of roof: ,V 4- <br /> SYSTEMS INFORMATION / SYSTEM Type (describe system) Size (capacity) Sizing talc. Efficiency p S Rating <br /> Air-conditioning system C e A. `rel \\ 7 ap‘ 0 0 C5 / <br /> Heating system L/ ` Q c t' 6 6 a "-r C) <br /> Ventilation ,� f <br /> Ducts Location: CJU , Co A. eL c ! ,c)- Fan Power: <br /> Piping Fluid design operating temp: Size of pipe: <br /> Hot water <br /> Electric power Drawings Y N Operations manual available upon completion: N <br /> Motors Open or enclosed Poles S speed Horsepower: <br /> �� r. AS Lighting power dens) a 1p <br /> Lighting Space type: - � � ° q g p density �' <br /> PRESCRIPTIVE MEASURES <br /> Components Section Requirements Check <br /> Operations Manual 102.1, 410, 413 Operations manual provided to owner. X. <br /> Windows & Doors 406.1.ABC.1.1 Glazed swinging entrance & revolving doors: max. 1.0 cfm /ft': all other products: 0.4 cfm/ft'. !` <br /> Joints /Cracks 406.1.ABC.1 To be caulked, gaskcted, weatherstripped or otherwise sealed. <br /> NA K <br /> Dropped Ceiling Cavity 406.1.ABC.1.4 Vented: seal & insulated ceiling. Unventcd seal & insulate roof & side walls. ,{� J� <br /> Reheat 407.1.BC Electric resistance reheat prohibited. ' -•f ' <br /> HVAC Efficiency 407.1, 408.1 Minimum efficiencies: Cooling Tables 407.I.ABC.3.2A -D; Heating Tables 407.I.ABC.3.2B, 407.I.ABC.3.2D, 408.!.ABC.3.2E K <br /> thru 408. LABC.3.2G. <br /> HVAC Controls 407. LABG2 Zone controls prevent reheat (exceptions); separate thermostatic control per zone; combined HAC control 5 ° F deadband • <br /> (exceptions). y <br /> Ventilation 409.1 .ABC.3 Motorized dampers regd. except gravity dampers OK in: 1) exhaust systems and 2) systems with design outside air intake or exhaust <br /> capacity 5300 cfm. . <br /> HVAC Ducts 410.1 ABC Air ducts, fittings, mechanical equipment & plenum chambers shall be mechanically attached, sealed, insulated & installed per Sec. <br /> 410.1.ABC. Fan power limitations. <br /> Balancing 410.!.ABC.4 HVAC distribution system(s) tested & balanced. Report in construction documents. 7 <br /> Piping Insulation 41 LI.ABC In accordance with Table 411.1.ABC.2. x ! <br /> Water Heaters 412.I.ABC Performance requirements in accordance with Table 412.1.ABC.3. Heat trap required. N. <br /> Swimming Pools 412.1.ABC.2.6 Cover on heated pools; Time switch (exceptions): Readily accessible on /off switch. /117T' { <br /> Hot Water Pipe Insulation 412.I.ABC.4 Table 411.I.ABC.2 for circulating systems. first 8' outlet pipe from storage tank, between inlet pipe and heat trap. ��r / <br /> Water Fixtures 412.1.ABC.2.5.2 Shower heat water flow restricted to 2.5 gpm at 80 psi. Public lavatory fixture max. Flow 0.5 gem; if self -closing valve 0.25 gallon 1411 <br /> „ <br /> circulating, 0.5 gallon noncirculating. <br /> Automatic control required for interior lighting in buildings <5,000 s.f.; Space control; Exterior photo sensor; Tandem wiring where R h/�.. <br /> Lighting Controls 415.1 ABC <br /> 1 -3 linear fluorescent lumps >30W. � <br /> If required by Florida law, I hereby certify that the system design is in compliance with the Florida energy code. Registration number <br /> ARCHITECT: - - - - -- <br /> ELECTRICAL SYSTEM DESIGNER: - <br /> LIGHTING SYSTEM DESIGNER: <br /> • MECHANICAL SYSTEM DESIGNER: <br /> PLUMBING SYST 1 ESIGNER: . <br /> 1 1 hereby certify tha �•'ans an pecifications covered by the calculation are in compliance Review of plans and specifications covered by this calculation indicates compliance with the <br /> with the Florida Ene e. S Florida Energy Code. Before construction is co pl this uilding will be inspected tor <br /> PREPARED BY: 'kid DATE: 1� — / � d I comp ce in •0 nee with Section • .9r:, F. • I hereby certify that this • ' g'� c. t .. 1 itI the Florida Energy Code• B L: . . <br /> OWNER AGENT: , , .— Zle. DATE: (es VVV DATE: <br /> /. / <br /> FLORIDA BUILDING CODE — BUILDING 13 -D.5 <br /> I, <br />