• FORM 600A -2004R EnergyGauge® 4.5.2 <br /> FLORIDA ENERGY EFFICIENCY CODE <br /> FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs <br /> Residential Whole Building Performance Method A <br /> Project Name: Rose Duplex Left Side Builder: Hur burt Co st uction, Ij�c. <br /> Address: �? <br /> Pe Office: G 4{ DI if MI <br /> �� 1 j�.v$e Ltt, n� <br /> City, State: Permit Number: 86 y <br /> 0 t 9 (K. ( <br /> Owner: 2 e �S i T L ) 35 ' (Z. Jurisdiction Number: 600 <br /> Climate Zone: Central <br /> 1. New construction or existing New 12. Cooling systems <br /> 2. Single family or multi - family Multi- family _ a. Central Unit Cap: 18.0 kBtu/hr <br /> 3. Number of units, if multi- family 1 SEER: 13.00 <br /> 4. Number of Bedrooms 2 _ b. N/A <br /> 5. Is this a worst case? No <br /> 6. Conditioned floor area (ft 814 ft c. N/A <br /> 7. Glass type I and area: (Label regd. by 13- 104.4.5 if not default) <br /> a. U- factor: Description Area 13. Heating systems <br /> (or Single or Double DEFAULT) 7a. (Sngle Default) 51.6 ft a. Electric Heat Pump Cap: 18.0 kBtu /hr __ <br /> b. SHGC: HSPF: 8.00 <br /> (or Clear or Tint DEFAULT) 7b. (Clear) 51.6 ft b. N/A <br /> 8. Floor types <br /> a. Slab -On -Grade Edge Insulation R =0.0. 122.0(p) ft c. N/A <br /> b. N/A <br /> c. N/A 14. Hot water systems <br /> 9. Wall types a. Electric Resistance Cap: 40.0 gallons <br /> a. Concrete, Int Insul, Adjacent R -4.1, 296.0 ft _ EF: 0.92 <br /> b. Concrete, Int Insul, Exterior R=4.1, 590.0 ft b. N/A <br /> c. N/A <br /> d. 1\1, A c. Conservation credits <br /> e. N/A (HR -Heat recovery, Solar <br /> 10. Ceiling types DHP- Dedicated heat pump) <br /> a. Under Attic R =30.0, 814.0 ft 15. HVAC credits <br /> b. NiA (CF- Ceiling fan, CV -Cross ventilation, <br /> c. N/A HE-Whole house fan, <br /> 11. Ducts PT- Programmable Thermostat, <br /> a. Sup: Unc. Ret: Unc. AH(Sealed):Interior Sup. R =6.0, 100.0 ft MZ- C- Multizone cooling, <br /> b. N/A MZ- H- Multizone heating) <br /> Total as -built points: 10220 <br /> Glass /Floor Area: 0.06 Total base points: 11489 PASS <br /> I hereby certify that the plans and specifications covered by Review of the plans and .•••••"- '''•••••. <br /> this calculation are in com li ce with the F rida ergy specifications covered by this " xE.ST9rR <br /> Code. ' calculation indicates compliance _ = :', ; <br /> PREPARED BY l7 with the Florida Energy Code. ` b ° ' r <br /> DATE: �-e91 Befo construction is completed g 4 I <br /> this building will be inspected for 0 ... a <br /> I hereby certify that this • uildi g, as de ed, • ' in� / compliance with Section 553.908 ;t„� <br /> •• Florida Statutes. <br /> compliance with the Fl grid- ergy o <br /> .�'' <br /> / Op W8'T�;: <br /> OWNER/AGENT: , , la , �; ., V$, f _ BUILDING OFFICIAL: <br /> DATE: I - DATE: 3"c) .Q' / <br /> 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2 &4. <br /> EnergyGauge® (Version: FLRCPB v4.5.2) <br />