Manual J Summer Calculations <br /> Residential Load - Component Details (continued) <br /> Project Title: Code Only <br /> Rose Duplex Left Side Professional Version <br /> Climate: Central <br /> 2/4/2009 <br /> W ` OTALS <br /> Sensible Envelope Load All Zones 7851 Btuh <br /> Sensible Duct Load 2151 Btuh <br /> Total Sensible Zone Loads 10002 Btuh <br /> Sensible ventilation 0 Btuh <br /> Blower <br /> 0 Btuh <br /> Whole House Total sensible gain 10002 Btuh <br /> Totals for Cooling Latent infiltration gain (for 56 gr. humidity difference) 1322 Btuh <br /> Latent ventilation gain 0 Btuh <br /> Latent duct gain 503 Btuh <br /> Latent occupant gain (4 people c 200 Btuh per person) 800 Btuh <br /> Latent other gain 0 Btuh <br /> Latent total gain 2625 Btuh <br /> TOTAL GAIN 12627 Btuh <br /> T I <br /> 1. Central Unit # I 18000 Btuh <br /> *Key: Window types (Pn - Number of panes of glass) <br /> (SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint) p ,y <br /> (U - Window U- Factor or'DEF' for default) <br /> (InSh - Interior shading device: none(N), Blinds(B), Draperies(D) or Roller Shades(R)) <br /> (ExSh - Exterior shading device: none(N) or numerical value) <br /> - Insect screen: none(N), Full(F) or Half(H)) M(iO4t1At.1 <br /> (Ornt - compass orientation) <br /> Version 8 <br /> For Florida residences only <br /> EnergyGauge® FLRCPB v4.5.2 Page 2 <br />