Laserfiche WebLink
)1 M 600A -2004R EnergyGauge® 4.5.2 <br /> Code Compliance Checklist <br /> Residential Whole Building Performance Method A - .Details • <br /> ADDRESS: , , , PERMIT #: I, <br /> 6A -21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> -- .— ._ —..._ <br /> COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK' • <br /> Exter(QC Windows & 606.1A60.1.1 Maxirrtum :3 cfm /sq.tt. window area. .5 cfm(sa.ft. door area. <br /> Exterior & Adjacent Walls 806.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall <br /> foundation & wall sole or sill plate; joints between exterior Wall panels at comers; utility <br /> { penetrations; between wall panels & top/bottorn plates; between walls and floor. <br /> EXCEPTION: Frame walla where a oontinuous infiltration barrier is installed that extends <br /> _.— ......... _ from. and Is $0010 00, the foundation to the top plate. <br /> Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by trued or joint members. <br /> EXCEPTION: Frame floors where a continuous Infiltration barrier is installed that is sealed <br /> __. _ _ _•, to the perimeter, penetrations and seams. <br /> Ceilings 606.1,ABC,1.2,3 Between wails & ceilings; penetrations of ceiling plane of top floor, around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate; ' <br /> attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> _ installed thatA sealed at the perimeter, at penetrations and seams <br /> Recessed Lighting Fixtures 606 1.ABC.1,2.4 Type IC rated with no penetrations, sealed; or Type IC or non -10 rated, installed inside a <br /> sealed box with 112" clearance & 3" from Insulation; or Type IC rated with < 2.0 cfm from <br /> egnditioned space, tested. <br /> MuhNstory Houses 606.1.AEIC.1.2,¢Air barter on perimeter of floor cayr between floors, ^ - -' <br /> Additional Infiltration reqts 606.1 ABC.1.3 Exhaust fans vented to outdoors. dampers: combustion space heaters comply with NFPA, • <br /> have combustion air. .... ;. <br /> 6A -22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) • ' • • <br /> COMPONENTS SECTION _ _. REQUIREMENTS <br /> Water Heaters 612.1 Comply with effici <br /> p y ency requirements In Table 612.1 ABC.3.2. Switch or clearly marked sir - •, , <br /> breaker (electriclor cutoff (gas) must beprovided. External or built -in heat trap required. <br /> Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non - commercial pools , <br /> must have a pump timer. Gas spa & pool heaters must have a minnnum thermal <br /> _.... ... _. efficienci et78°%. .. ..^ • <br /> Shower heads 612.1 _ -- — Water flow must bg restricted to no more than 2.5 gallons per minute at 80 PSIG. • <br /> Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> ' attached, sealed, Insulated, and Installed in accordance with the criteria of Section 610. • <br /> _ Ducts In unconditIongkl attics: R -6 min. Insulation. <br /> HVAC Cgntlgls 607.1 Separate regsjly accessible manual or automatic thermostat for each system_ <br /> Insulation 804.1, 602.1 Ceilings -Min. R -19. Common walls - Frame R -11 or CBS R-3 both Sides. <br /> Common ceiling & floors R -11. <br /> »'t,c 4• <br /> EnergyGaugem' DCA Form 600A -2004R EnergyGauge l/FlaRES'2004R FLRCSB v4.5.2 <br /> • <br />