Laserfiche WebLink
' /RM 600A -2004R EnergyGauge® 4.5.2 <br /> Code Compliance Checklist • <br /> Residential Whole Building Performance Method A - ,Details <br /> ADDRESS: , , , PERMIT #: <br /> 6A -21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> COMPONENTS SON " <br /> - • . .... . ECTI <br /> .. REQUIREMENTS FOR EACH PRACTICE — — -� - _ _..._ _ ... <br /> ' <br /> CHECK' <br /> Exterig( Windows &Doors 806.1 ABC.1,1 Maximum:.3 cfm /sq.ft. window area' .5 cfnl/sa.ft. door area. — - -... -� <br /> Exterior & Adjacent Walls 608.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windOWS/doors & frames, surrounding wall; . . <br /> foundation & wall sob or sill plate; joints between exterior Wall panels at comers; utility <br /> penetrations; between wall panels & top/bottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from, and is sealegjo, the foundation to the top plate. . <br /> Floors 608.1.ABC•1.2.2 Penetrations /openings >1/6" sealed unless backed by trus9 or joint Members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed ' <br /> -- _. • _Je the perimeter, penetrations and seams. <br /> Ceilings 608.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor, around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate; ' <br /> attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is r <br /> installed that sealed at the perimeter, at penetrations and seams. _ <br /> • <br /> Recessed Lighting Fixtures 606.1 .ABC. t.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed Inside a - -� • <br /> sealed box with 1/2" clearance & 3" from Insulation; or Type IC rated with < 2.0 dm from <br /> - - -- _ —.. . Conditioned space, tested. <br /> Muses 606.1.ABC.1.2. it barrier on perimeter of floor caul between floors, <br /> � ---� - P �t e n ' • <br /> Additional Infiltration reqts 606.1ABC.1.3 Exhaust fans vented to outdoors. dampers: combustion space heaters comply with NFPA, <br /> have combustion air. <br /> 6A -22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by ali residences.) . <br /> ' , COMPONENTS SECTION _. - REQUIREMENTS <br /> Water Heaters 612,1 Comply with etftciency requirements In Table 612.1 ABC.3.2. Switch or Clearly marked cir <br /> —_— breaker (electric or cutoff as must beprovided. Extemal or built-in heat trap required. <br /> Swimming Pools & Spas 612,1 Spas & heated pools must have covers (except solar heated). Non - commercial pools ',. <br /> must have a pump timer. Gas spa & pool heaters must have a minirrlum thermal , • <br /> _ _.... ... _. efficien�A76 %.. <br /> Shower heads. • 612.1 Water flow mus{.ba restricted to no more than 2.5 gallons per minute at 80 P51G. <br /> Air Distribution Systems 610.t All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically ' <br /> attached, sealed, Insulated, and installed In accordance with the criteria of Section 610. i <br /> Ducts in uncondltbnetiottics: R -6 thin. insulation. <br /> HVAC Controls 607.1 SeDarate readily accessible manual or automatic therm for each s t - __... —_ --• -,_,,, r , - <br /> thermostat each system. <br /> Insulation 804.1, 502.1 Ceilings -Min. R -19. Common walls - Frame R -11 or CBS R-3 both Sides. — <br /> Common calling & floors R -11, • . • <br /> _ h� <br /> • <br /> EnergyGaugem" DCA Form 600A -2004R EnergyGauge4VFIaRES'2004R FLRCSB v4.5.2 <br />