Laserfiche WebLink
.,n 600A -2004K " r< eiyyvtiuyt , 4.u.c <br /> • <br /> FLORIDA ENERGY EFFICIENCY CODE <br /> FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs <br /> Residential Whole Building Performance Method A <br /> I Project Name: LH1531M- MARTINIQUE -1531 S.F. LIVING AREABuiider. LENIOR HO)IE , � , <br /> Address: Permitting Office: L'i 0 Z yr - 1 !S , <br /> City, State: <br /> Owner Jurisdiction Number. 6p//6 '??. <br /> Climate Zone: Central Parrett Num i�6 � <br /> • <br /> 1. New construction or existing - - -� New _ 12. fooling systems . <br /> 2. Single family or multi -wily Multi- family - a. Central Unit Cap: 28.2 kBtu/hr _ '• ' • • <br /> 3. Number of units, if multi - family 1 SEER: 14.00 <br /> 4. Number of Bedrooms 2 _- b. N/A - <br /> 5. Is this a worst case? . Yes _ - <br /> 6. Conditioned floor area (ft 1531 ft _ c. N/A <br /> 7. Glass typal and area: (Label regd. by 13- 104.4.5 If not dolimb.) <br /> a. U- factor: Description Area 13. Heating systems • <br /> (or Single or Double DEFAULT) la(Sngle Default) 127.0 ft - a. Electric Heat Pump Cap: 28.2 kBtu/br ' <br /> b. SHGC: <br /> HSPF: 8.20 • (or Clear or Tint DEFAULT) 7b. (Clear) 127.0 ft' _ , b. N/A _. . _' <br /> 8. f typtx - <br /> a. Slab -On -Grade Edge Insulation R '0.0, 36.0(p) fl _- o. N/A <br /> b. Raised Wood, Post or Pier R= 11.0, 112.0f1 - - <br /> c. N/A 14. Hot water systems ) <br /> 9. Wall types a. Electric Resistance <br /> Cap: 40.0 gallons - <br /> a. Concrete, Int Instil, Exterior R=4.1, 389.0 0.2 - EF: 0.92 <br /> b. N/A b. NIA -. <br /> c. N/A <br /> d. N/A _ c. Conservation credits : ! _' <br /> - e. N/A - (HR Heat recovery, Solar - <br /> 10. Ceiling types _ DHP- Dedicated heat pump) ) . • <br /> a. Under Attic R=30.0, 866.0 Al 15. tfVAC credits • <br /> b. N/A _ (CP- Coifing fan, CV -Cross ventilation, <br /> c. N/A _ HF -Whole house tan, . <br /> • <br /> 11. Duels PT- Programmable Thermostat, • - <br /> a. Sup: Ono. Rd: Con. AH(Sealed):Interior Sup. R=6.0, 150.0 ft MZ- C- Multizone cooling, <br /> b. N/A - M'L- H= Multizons beating) . _ ._ _______ . L _ t <br /> . __________...________ ... _ . <br /> Glass/Floor Area: 0.08 Total as- built points: 14112 . •. <br /> • <br /> ..; <br /> . ., ____.. ______....... ____... Total base points, 16493 P ASS <br /> I hereby certify that the plans and specifications covered by Review of the plans and . 'r? <br /> this calculation are in comps ce ' e Florida E Tr <br /> y specifications Covered by this , 'o1E T <br /> ,,: 4th' • <br /> Code, calculation indicates compliance': 0 •' . <br /> PREPARED BY: /... with the Florida Energy Code. ; e v ' " • <br /> DATE: 456.- 2 41 , 'tea p Before wnstnu Lion is completed � =. - - - - - • <br /> this building will be inspected•for ;..0 " 4 - , 4 ,i 1 ;; <br /> ' <br /> 1 hereby certify that this building, as de '; l io • pliance compliance with Section 553.906 . -. . `, ..t ; F <br /> with the Florida Energy Code. / Florida Statutes. , .' ,. <br /> OWNER/AGENT: .11/ BUILDING OFFICIAL: <br /> DATE: ArL� - DATE: `3 --- 0 <br /> Iii glass type. For actu '' - and areas. see Sum <br /> ummer & Winter Glass output on pages 2&v4. - -- - - <br /> EnergyGauge® (Version: FLRCSB v4.5.2) <br />