Laserfiche WebLink
EnCon Services, Inc. <br /> Sign Design Calculations <br /> Job Description PREPARED BY: EnCon Services, Inc. <br /> Verizon Wireless 2272 Jaudon Road <br /> Dover, FL 33527 <br /> Zephyrhills, Florida 813 - 655 -3373 <br /> Verizon Wireless letters F 813 - 655 -9814 <br /> Design per 2007 Florida Building Code, 2009 supplement, Section 16 Wind Load <br /> ASCE 7 -05 Aaron Biedenbach, P.E. <br /> Design Specifications I FL PE #52949, FL EB 9394 <br /> Importance Factor 1 OH PE 60756, OC #01893 <br /> Kzt 1 KY PE #20281, P #2463 <br /> Exposure Factor B IN PE #PE 19600322 <br /> Kd 1 FL CBC #060535, QB #22527 <br /> Kz 0.7 <br /> V 110 mph <br /> GCp -GCpi 1.28 Zone 4, h < 60 <br /> Wind Pressure 27.8 (psf) <br /> Sign Information per Letter <br /> Height 1.34 (ft) <br /> Width 1.34 (ft) <br /> Thickness 1.00 (ft) <br /> Distance grade to top 30 (ft) <br /> Wind Sheer Force 37.19 (Ib) <br /> Weight of Sign 18 (Ib) <br /> Total Sheer Force = 0.00 (Ib) <br /> Total Tension Force = 49.84 (Ib) <br /> Required Provided <br /> Fastener size (Nominal) #12 -14 #12 -14 <br /> Minimum number of fasteners per letter 4 4 <br /> Sheer Force per fastener (Ib) 0.0 300 <br /> Tension Force per fastener (Ib) 12.5 125 <br /> Combination Tension and 0.10 <1 O.K. <br /> Sheer ratio <br /> FASTENER TO BE #12 -14 SELF DRILLING SCREW INTO METAL WALL PANELS. <br /> 4/2/2009 <br /> Verizon Wireless Zephyrhills 16in LTR5 <br />