My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
09-9595
Zephyrhills
>
Building Department
>
Permits
>
2009
>
09-9595
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2011 3:00:43 PM
Creation date
1/18/2011 3:00:41 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
09-9595
Building Department - Name
WELLESLEY DEVELOPMENT CORP
Address
5538 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EnCon Services, Inc. <br /> Sign Design Calculations <br /> Job Description PREPARED BY: EnCon Services, Inc. <br /> Little Caesars 6178 2272 Jaudon Road <br /> 5538 Gall Blvd Dover, FL 33527 <br /> Zephyrhills, FL 813 -655 -3373 <br /> 2ft 2in raceway F 813 -655 -9814 <br /> Design per 2007 Florida Building Code, 2009 supplement, Section 16 Wind Load <br /> ASCE 7 -05 Aaron Biedenbach, P.E. <br /> Design Specifications I FL PE #52949, FL EB 9394 <br /> Importance Factor 1 OH PE 60756, OC #01893 <br /> Kzt 1 KY PE #20281, P #2463 <br /> Exposure Factor B IN PE #PE 19600322 <br /> Kd 1 FL CBC #060535, QB #22527 <br /> Kz 0.7 <br /> V 120 (mph) <br /> GCp -GCpi 1.28 Zone 4, H < 60 Feet <br /> Wind Pressure 33.0 (psf) <br /> Sign Information <br /> Height 2.17 (ft) <br /> Width 12.75 (ft) <br /> Thickness 0.42 (ft) <br /> Distance grade to top 30 (ft) <br /> Wind Sheer Force 29.85 (Ib) <br /> Weight of Sign 276 (Ib) <br /> Total Sheer Force = 277.90 (Ib) <br /> r <br /> Total Tension Force = 912.60 (Ib) <br /> Required Provided <br /> Fastener size (Nominal) 3/8 3/8 <br /> Minimum number of fasteners 8 8 <br /> Sheer Force per fastener (Ib) 34.7 280 <br /> Tension Force per fastener (Ib) 114.1 352 <br /> Combination Tension and 0.45 <1 O.K. <br /> Sheer ratio <br /> THREADED ROD THROUGH WALL IS PREFERRED IN ALL INSTANCES. IF IT IS NOT POSSIBLE TO USE THREADED ROD, SEE CHART BELOW <br /> FOR APPROPRIATE ANCHOR SELECTION. SIZE AND NUMBER REQUIRED ARE NOTED IN THE CHART ABOVE. <br /> WALL STRUCTURE ANCHOR TYPE <br /> WOOD BLOCKING LAG BOLT (3" EMBEDMENT) THROUGH BLOCKING <br /> EIFS OVER 5/8" PLYWOOD LIBERTY TOGGLE BOLT OR THRU BOLT WITH SLEEVE <br /> HOLLOW CONCRETE BLOCK, BRICK SLEEVE ANCHOR (1 -1/2' EMBEDMENT) <br /> SOLID CONCRETE WEDGE ANCHOR (2 -1/2" EMBEDMENT) <br /> CMU, SOLID CONCRETE, BRICK HILTI HIT ROD W /HY -20 ADHESIVE (31/2" EMBEDMENT) <br /> ALL ANCHORS SHALL BE CHOSEN AND PLACED IN ACCORDANCE WITH MANUFACTURERS INSTALLATION <br /> INSTRUCTIONS <br /> 7/6/2009 <br /> Little Caesars Zephyrhils 26in raceway <br />
The URL can be used to link to this page
Your browser does not support the video tag.