Laserfiche WebLink
FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1531 MARTINQUE 214 O <br /> Street Builder Name: LENNAR <br /> City, State, Zip: TAMPA , FL , Permit Office: <br /> Permit Number ('� 70 „I, v T ((S <br /> Owner. LENNAR HOMES r. 9 (� 2 �[ �' ` l <br /> t <br /> Design Location: FL, Tampa Jurisdiction: l ((pcTr) <br /> 1. New construction or existing New (From Plans) 9. WaU Types <br /> 2. Single family or multiple fami Insulation Area <br /> IY MuUi family a. Concrete Block - Int Insul, Exterior R=4.1 541.33 ft <br /> 3. Number of units, if multiple family 1 b. N/A R= ft' <br /> ft <br /> 4. Number of Bedrooms d. N/A R= <br /> 2 d. N/A <br /> 5. Is this a worst case? R ft= <br /> Yes 10. Ceiling Types <br /> 6. Conditioned floor area OF) 1531 Insulation Area <br /> a. Under Attic <br /> (Vented) R =30.0 766.00 ft <br /> 7. Windows Description Area b. N/A R= f <br /> a. U- Factor. Dbl, U =0.60 100.98 ft c' WA R= <br /> SHGC: SHGC =0.32 11. Ducts <br /> b. U- Factor: SgI, U =1.17 40.00 ft a. Sup: Attic Ret Attic AH: Interior Sup. R= 6, 355 ft <br /> SHGC: SHGC =0.74 <br /> c. U- Factor: 12. Cooling systems <br /> N/A ft2 a. Central Unit <br /> SHGC: Cap: 34 kBtu/hr <br /> d. U- Factor. N/A ft SEER: 14 <br /> SHGC: 13. Heating systems <br /> e. U Factor. N/A a. Electric Heat Pump Cap: 34 kBtu/hr <br /> SHGC: <br /> HSPF: 8.2 <br /> 8. Floor Types Insulation Area 14. Hot water systems <br /> a. Slab -On -Grade Edge Insulation R=0.0 1531.00 ft2 a. Electric <br /> b. Raised Floor Cap: 40 gallons <br /> R =19.0 88.00 ft= EF: 0.92 <br /> c. N/A R= ft' b. Conservation features <br /> None <br /> 15. Credits <br /> Pstat <br /> Glass/Floor Area: 0.092 Total As -Built Modified Loads: 30.94 <br /> Total Baseline Loads: 38.54 PASS <br /> 1 hereby certify that the plans and specifications covered by ..•••••••••••••••. <br /> this calculation are in compliance with the Florida Ene y Review of the plans and VIE ST <br /> Code. rgY specifications covered by this : 4�y A <br /> calculation indicates compliance 1. ' 4 ' ; '""%. <br /> ? *, <br /> \ <br /> with the Florida En : �' t <br /> PREPARED BY: ` � <br /> I :` , . _ 'a, s' ' .� <br /> DATE: \v Before construction is Code• <br /> plated tarr`- _ ; <br /> IIP <br /> this building will be inspected for i Y - <br /> compliance with Section 553.908 , i �- n. <br /> I hereby certify that this building, as desig Florida Statutes. <br /> 9I .. mpliance 4 4, a ° <br /> with the Florida Energy Code. . <br /> OWNER/AGENT: Alli BUILDING OFFI IAL: ____LLY-- .... <br /> '�►�, <br /> DATE: <br /> DATE: _4_0_: -©7 <br /> ` <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory- sealed in accordance with NI110.A.3. <br /> 3/24/2009 2:51 PM EnergyGauge® USA - FlaRes2008 <br /> Page 1 of 5 <br />