Laserfiche WebLink
D • <br /> FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1531 MARTINQUE 214 D Builder Name: LENNAR <br /> Street Permit Office: Ci4 D z I� <br /> City, State, Zip: TAMPA , FL , 114'53 �p K r h l is <br /> Permit Number: <br /> Owner. LENNAR HOMES Jurisdiction: (P 1 i bao <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types <br /> Insulation Area <br /> 2. Single family or multiple family Muni family a. Concrete Block - Int Insul, Exterior R=4.1 541.33 ft' <br /> 3. Number of units, if multiple family 1 b. N/A R= ft' <br /> c. N/A R= ft2 <br /> 4. Number of Bedrooms 2 d. N/A <br /> R= ft <br /> 5. Is this a worst case? Yes 10. Ceiling Types <br /> Insulation Area <br /> 6. Conditioned floor area (ft2) 1531 a. Under Attic (Vented) R =30.0 766.00 ft <br /> 7. Windows Description Area b. N/A R= ft= <br /> a. U- Factor. DbI, U =0.60 100.98 ft c' N/A R= ft <br /> SHGC: SHGC =0.32 11. Ducts <br /> b. U- Factor: Sgl, U =1.17 40.00 ft= a. Sup: Attic Ret Attic AH: Interior Sup. R= 6, 355 ft <br /> SHGC: SHGC =0.74 12. Cooling systems <br /> c. U- Factor. N/A ft a. Central Unit <br /> SHGC: Cap: 34 kBtu/hr <br /> d. U- Factor. N/A ft , SEER: 14 <br /> SHGC: 13. Heating systems <br /> a. Electric Heat Pump Cap: 34 kBtu/hr <br /> e. U-Factor N/A ft2 <br /> SHGC: HSPF: 82 <br /> 8. Floor Types Insulation Area 14. Hot water systems <br /> a. Slab-On-Grade Edge Insulation R".1.0 1531.00 ft2 a. Electric Cap: 40 gallons <br /> b. Raised Floor R= 19.0 88.00 ft EF: 0.92 <br /> b. Conservation features <br /> c. N/A R= ft <br /> None <br /> 15. Credits Pstat <br /> Glass/Floor Area: 0.092 Total As -Built Modified Loads: 30.94 PASS <br /> Total Baseline Loads: 38.54 <br /> 1 hereby certify that the plans and specifications covered by Review of the plans and '" " <br /> this calculation are in compliance with the Florida Energy : �THE STg " <br /> Code. rgY specificat covered by this o _ �AO'•. <br /> calculation indicates compliance ' • '' " ' ' s �' <br /> PREPARED BY: \ �o with the Florida Ene Code " ' ������ `: <br /> \l. Before is n/fl ' E w (, <br /> DATE: construction is completed ` -�" � .st � E : <br /> : <br /> MI this building will be inspected for "`_ D <br /> compliance with Section 553.908 ' 0 k ! :n, a <br /> I hereby certify that this building, as desig s compliance Florida Statutes. * ,6• D Z.; <br /> with the Florida Energy Code. / y"S <br /> OWNER/AGENT: f BUILDING OFFICIAL: �� 0 <br /> .... ............... ............ <br /> DATE: i DATE: /e /3 -z.? - Compliance requires certiff ► . y the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory- sealed in accordance with NI110.A.3. <br /> 3/24/2009 2:51 PM EnergyGauge® USA - FlaRes2008 <br /> Page 1 of 5 <br />