Laserfiche WebLink
NOTE: INSTALL ANCHORS Revisions: <br /> PER MANUFACTURER'S Details for Concrete Insta 0 4/01/2009 Plan Update With Detail Updates <br /> REQUIREMENTS <br /> SIMPSON "LSTA18" 20 GA. <br /> STRAP TIE FASTENED WITH <br /> GUSSET ANGLE SIMPSON (14) -10D NAILS <br /> • STRONG TIE HGAM I OKT HDG (7- FASTENERS PER MEMBER) <br /> (OR EQUIVALENT) SPACED 4" OC <br /> 5/8" DIA.x3" LAG BOLT WITH 2" <br /> (4) -SDS WOOD SCREWS 1/4" DIA. WASHER, 3° EMBEDMENT A449 <br /> x2Y2" HOT DIPPED GALVANIZED GALVANIZED OR EQUIVALENT <br /> (2)-2x6 PRESSURE (4) 1/4" x 3 -1/4" ANCHOR 110 MPH WIND ZOND- (i, - ''%' % ' °%� <br /> TREATED SKIDS VV <br /> %'' % "%'%-, <br /> SIMPSON WEDGE -ALL 5/8" DIA. X 40" GROUND ANCHOR -I <br /> P` WA253 I 4MG (OR EQUIVALENT) WITH SINGLE 6" HELIX AA �` <br /> (MODEL #59060) FOR SOIL CLASS 3 <2(‹c-, I s <br /> ��� 130 AND 150 MPH WIND ZONE `)�' ' ' <br /> 4" THICK CONCRETE SLAB ® 5/8" DIA. X 48' GROUND ANCHOR • • ',' I ? f - �i~` <br /> WITH SINGLE 6" HELIX i! / . / . <br /> (MODEL #59065) FOR SOIL CLASS 3 j ;- <br /> MIN. 4" OFFSET FROM EDGE (SEE CHART FOR QUANTITY) v <br /> Details for Masonry Block Installations <br /> 3/ 16" GALVANIZED CABLE TIE <br /> DOWN ENGINEERING PART SIMPSON "LSTA 18" 20 GA. <br /> #5 1 556 (OR EQUIVALENT), STRAP TIE FASTENED WITH <br /> TIGHTEN TO 500 LBS OF TENSION (2) -2x6 PRESSURE (1 4) - I OD NAILS <br /> TREATED SKIDS (7- FASTENERS PER MEMBER) <br /> USE (3) -3/10" GALVANIZED CLAMP <br /> TIE DOWN ENGINEERING PART (F +" 5/8" DIA.x3" LAG BOLT WITH 2" <br /> #53806 (OR EQUIVALENT) �� WASHER, 3" EMBEDMENT A449 <br /> �/ \ I .V,,: 1.' "x 1 ti� GALVANIZED OR EQUIVALENT <br /> 110 MPH WIND ZOND- >// % ECLOCK - / j Y, <br /> 1/2" DIA. X 30" GROUND ANCHOR ›\ ' >* � I I O MPH WIND ZOND r <br /> ' I /. \� ���� <br /> WITH SINGLE 4" HELIX \ !,/,,./<%" ' \" , 5/8" DIA. X 40" GROUND ANCHOR +)F" <br /> (MODEL #59055) FOR SOIL CLASS 2 ,mil i� 4' WITH SINGLE 6" HELIX - <br /> 130 AND 150 MPH WIND ZONE - s \ ! . �; (MODEL #59060) FOR SOIL CLASS 3 2' 4 �" • <br /> 4 %,8'x 16`� <br /> 5/8" DIA. X 40" GROUND ANCHOR / % /•• 130 AND 150 MPH WIND ZONE ./ it BLOCK- <br /> WITH SINGLE 6" HELIX \% ` , �, 5/8" DIA. X 48" GROUND ANCHOR l i /. /. 4' // <br /> (MODEL #59060) FOR SOIL CLASS 3 ' \ / \ \/ WITH SINGLE 6" HELIX . 1. ‘ `' \ <br /> (SEE CHART FOR QUANTITY) ;; \ //' (MODEL #59065) FOR SOIL CLASS 3 ;\ ±' 1' <br /> GENERAL NOTES (SEE CHART FOR QUANTITY) / <br /> 1. DESIGN FOR MIN 2,500 P51 CONCRETE <br /> 2. ALL HELIX ANCHORS MUST MEET THE MINIMUM WORKING LOAD OF 3,150 1b5. AND <br /> ULTIMATE LOAD OF 4,725 lbs.; ANCHORS MUST BE INSTALLED TO <br /> MANUFACTURERS RECOMMENDATIONS. ANY BENDING OR DAMAGE CAUSED UPON ANCHOR CHART <br /> INSTALLATION WILL VOID ANCHOR AND MUST BE DISCARDED. <br /> 3. CONTRACTOR SHALL VISIT THE SITE AND THOROUGHLY FAMILIARIZE THEMSELF <br /> WITH EXISTING CONDITIONS. CONTRACTOR 15 RESPONSIBLE FOR MEETING SOIL P4.00K 110 MpN 130 MPh - ,j' 0 MFH <br /> CLASSIFICATION FOR SIZING HELICAL ANCHORS. GULDIN6 9,Acit - <br /> 4. ONE ANCHOR SHALL BE PLACED AT EACH BUILDING CORNER WITHIN 12" OF <br /> WPM 1-M16111 (MAX) # MOCK' '* KI17 4 A IG110ftS EhCV1 �E) <br /> 6 10 7' 4 2 <br /> CORNER 6 12 7' - 6" 4 2 2 2 <br /> 5. ANY REQUIRED INTERMEDIATE ANCHORS SHALL BE PLACED EQUAL DISTANCES 8 8 7' -b" 4 7 7 2 - <br /> APART FROM EACH OTHER. 8 10 7' 6" 9 2 3 7 <br /> G. THE ANCHOR MUST BE IN THE SITE SOIL CLASS IN WHICH THE LOAD 8 12 %'-6" 6 - 2 2 <br /> REQUIREMENTS WERE SET, 3 14 ' 6" 6 - 5 5 <br /> 7. USE TIE -DOWN ENGINEERING (OR COMPARABLE) 1/2" X 30" GROUND ANCHOR 8 16 7' - 6" 6 7 5 3 5 <br /> WITH SINGLE 4" HELIX OR 5/8" DIA. X 40" GROUND ANCHOR WITH SINGLE 6" HELIX 10 10 7' 4 - - <br /> 8. TESTED SOIL CAPACITY FOR TIE DOWN 1/2" X 30" ANCHOR = 500 FT . LB. 10 12 7' - 0" 6 _ 2 3 <br /> 9. TESTED SOIL CAPACITY FOR TIE DOWN 5/8" X 40" ANCHOR = 375 FT. LB 10 19 7' O" 6 <br /> 10 Ib 7'-O" 6 2 5 5 5 <br /> 10 INSTALLATION OF THE ANCHORS MUST MEET ALL AT REQUIREMENTS AS SPECIFIED 10 20 7' -0" 3 - 3 5 5 <br /> BY TIE DOWN ENGINEERING, INC TO INCLUDE REQUIREMENTSINS FOR SPACING AND 10 24 7 ' -O" 10 -. 4 4 4 <br /> SITE SPECIFIC SOIL CONDITIONS 10 30 7' - 0" (7 2 - 5 5 ' <br /> 1 I . MAXIMUM STRUCTURE HEIGHT 15 12 FEET 12 12 6' -6" 6 2 2 7 <br /> 12. ANCHORS ARE FOR SPECIFIED SOIL CLASSES NEEDED 12 14 6' -6" 6 2 5 5 5 <br /> DESIGN PARAMETERS 12 16 6' -6" 6 = 3 5 . 5 <br /> 12 20 6'-6" d 5 5 5 <br /> I . WIND DESIGN PER ASCE 7 -02 12 24 6' -6" 10 2 9 4 4 <br /> 2. DESIGN WIND SPEED - I I OMPH - 130MPH - 150 MPH 12 50 6' -6" 12 2 5 ' 5 <br /> 3. WIND EXPOSURE CATEGORY: C 12 56 b 6 19 2 b 6 6 <br /> 12 90 6'-6" 16 _ 7 7 <br /> 4. WIND IMPORTANCE FACTOR: 1 .0 12 44 b' b" lb _ 7 7 _ <br /> 5. ENCLOSURE CLASSIFICATION: ENCLOSED 12 50 6' - 6" 18 2 8 8 0 <br /> G. DESIGN MEETS INTERNATIONAL BUILDING CODE 200G 4 FLORIDA BUILDING CODE 19 14 6'-6" 17 4 3 5 5 <br /> 2007 4 2009 SUPPPLEMENTS TO FLORIDA BUILDING CODE 2007 14 16 6'-6" 12 4 5 5 5 <br /> SOIL CLASS DESCRIPTIONS: 14 20 6' -6" 46 4 5 5 5 <br /> 14 29 b' - 6" 20 4 4 9 9 <br /> SOIL CLASS 2 - VERY DENSE AND OR CEMENTED SANDS, COARSE GRAVEL, 14 30 6' - 6" 24 4 r, 5 <br /> COBBIES, PRELOADED SILTS, CLAYS AND COARL. A TEST PROBE TORQUE VALUE OF 14 56 6' -6" 28 9 6 b 6 <br /> 14 40 6' - 6" 52 4 7 7 <br /> _ <br /> 550 +Ibs -in 14 44 6' -6" 52 4 7 8 ' <br /> SOIL CLASS 3 - MEDIUM DENSE COARSE SANDS SANDY GRAVELS VERY STIFF SILTS 14 50 6' -6" 36 4 8 0 0 <br /> AND CLAYS. A TEST PROBE TORQUE VALUE OF 350- 550Ibs -1n <br /> DESIGN FOR: <br /> LARK BUILDERS <br /> 409 DICKSON STREET A i•••• •. • <br /> ::::::::' Haney Associates, Inc. <br /> VIDALIA, GA. 30474 ■••••••� <br /> • : : : :r Engineering & Construction Planning <br /> PROJECT NUMBER - OGEN224A 1••• <br /> • i 1N Vasa Street, SdMedi, Pendleton, SC SOO - Phone: 864446-76N Fu: 864-646 -7999 <br /> DATE: APRIL 15t, 2009 <br /> Sheet I OF I <br /> e R'a: <br /> . ".- ,. • 1� �+ <br /> 'A 6J� i�. ......,_\ <br /> a ir. ; <br /> NOTE: TIlIS PLAN HAS BEEN UPDATED AND SUPERSEDES ANY PREVIOUS COPIES + * * k , 0 j)ei ;f1e,, «,,,t,Ab0. <br />