My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
09-9845
Zephyrhills
>
Building Department
>
Permits
>
2009
>
09-9845
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2011 2:49:34 PM
Creation date
1/19/2011 2:49:31 PM
Metadata
Fields
Template:
Building Department
Company Name
EILAND PARK TOWNHOMES
Building Department - Doc Type
Permit
Permit #
09-9845
Building Department - Name
LENNAR HOMES INC
Address
37668 AARALYN RD BLDG 6 51
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WINDOWS <br /> Window orientation below is as entered. Actual orientation is modified by rotate angle shown in "Project' section above. <br /> / ' Overhang <br /> V # Omt Frame Panes NFRC U- Factor SHGC Storms Area Depth Separation Int Shade Screening <br /> 1 N Metal Low -E Double Yes 0.6 0.32 N 31.5 ft 1 ft 0 in 10 ft 0 in HERS 2008 None <br /> 2 E Metal Low -E Double Yes 0.6 0.32 N 63 ft 1 ft 0 in 10 ft 0 in HERS 2008 None <br /> 3 N Metal Low -E Double Yes 0.6 0.32 N 31.5 ft 1 ft 0 in 1 ft 5 in HERS 2006 None <br /> 4 N Metal Low -E Double Yes 0.6 0.32 N 9 ft' 1 ft 0 in 1 ft 5 in HERS 2006 None <br /> 5 E Metal Low -E Double Yes 0.6 0.32 N 47.25 ft 1 ft 0 in 1 ft 5 in HERS 2006 None <br /> INFILTRATION & VENTING <br /> / — Forced Ventilation — Run Time Fan <br /> V Method SLA CFM 50 ACH 50 ELA EqLA Supply CFM Exhaust CFM Fraction Watts <br /> Default 0.00036 1295 6.03 71.1 133.7 0 cfm 0 cfm 0 0 <br /> COOLING SYSTEM <br /> V # System Type Subtype Efficiency Capacity Air Flow SHR Ductless <br /> 1 Central Unit None SEER: 14 28 kBtu /hr 840 cfm 0.75 False <br /> HEATING SYSTEM <br /> J # System Type Subtype Efficiency Capacity Ductless <br /> 1 Electric Heat Pump None HSPF: 8.2 28 kBtu /hr False <br /> HOT WATER SYSTEM <br /> V # System Type EF Cap Use SetPnt Conservation <br /> 1 Electric 0.92 _ 40 gal 60 gal 120 deg _ None <br /> SOLAR HOT WATER SYSTEM <br /> V FSEC Collector Storage <br /> Cert # Company Name System Model # Collector Model # Area Volume FEF <br /> None None ft2 <br /> DUCTS <br /> / - Supply — — Return — Air Percent <br /> V # Location R -Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF <br /> 1 Attic 6 265 ft Attic 8 ft Default Leakage Interior <br /> 3/24/2009 1:29 PM EnergyGauge® USA - FlaRes2008 Page 3 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.