Laserfiche WebLink
FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1531 MARTINQUE 214 D Builder Name: LENNAR <br /> Street: • 37/ 7Z 4 /7/Z19 1 -y"/ #j. Permit Office: wJ D � Z�`tyr -N: HI City, State, Zip: TAMPA , FL , / Permit Number: B y7 <br /> Owner. LENNAR HOMES Jurisdiction: 4, f it, <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area <br /> a. Concrete Block - Int Insul, Exterior R =4.1 541.33 ft <br /> 2. Single family or multiple family Multi family <br /> 3. Number of units, if multiple family 1 b. N/A R= ft' <br /> c. N/A R= ft <br /> 4. Number of Bedrooms 2 d. N/A R= ft2 <br /> 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area <br /> 6. Conditioned floor area (ft 1531 a. Under Attic (Vented) R =30.0 766.00 ft <br /> 7. Windows Description Area b. N/A R= ft2 <br /> a. U- Factor: Dbl, U =0.60 100.98 ft c' N/A R= <br /> SHGC: SHGC =0.32 11. Ducts <br /> b. U- Factor: Sgl, U =1.17 40.00 ft= a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 355 ft <br /> SHGC: SHGC =0.74 12. Cooling systems <br /> c. U- Factor: N/A ft2 a. Central Unit Cap: 34 kBtu/hr <br /> SHGC: <br /> d. U- Factor: N/A ft' SEER: 14 <br /> SHGC: 13. Heating systems <br /> a. Electric Heat Pump Cap: 34 kBtu /hr <br /> e. U- Factor: N/A ft2 <br /> SHGC: HSPF: 8.2 <br /> Types 14. Hot water systems <br /> 8. Floor T <br /> YP Insulation Area a. Electric <br /> a. Slab -On -Grade Edge Insulation R =0.0 1531.00 ft' Cap: 40 gallons <br /> b. Raised Floor R =19.0 88.00 ft <br /> c. N/A b. Conservation features EF: 0.92 <br /> R= ft <br /> None <br /> 15. Credits Pstat <br /> Glass /Floor Area: 0.092 Total As -Built Modified Loads: 30.94 PASS <br /> Total Baseline Loads: 38.54 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ° F t1 E S A ' <br /> this calculation are in compliance with the Florida Energy specifications covered by this O . . . 4 4,N. <br /> Code. ,���� O ' <br /> calculation indicates compliance $14?.. o . �•' •., .:T --$ s�' \ <br /> PREPARED N ' <br /> PREP BY: DOA with the Florida Energ Code <br /> Before construction is completed ° ; a �� ; ° '` °� "` q .. N : .N .� . O w >-a b , <br /> DATE: this building will be inspected for .O ii "- <br /> ' mac <br /> compliance with Section 553.908 , ` . .e ' r <br /> I hereby certify that this building, as design; • - •mpliance Florida Statutes. `• • • te r ,. <br /> with the Florida Energy Code. • <br /> OWNER/AGENT: , r <br /> ,/ � CO � � BUILDING O FI IAL. <br /> DATE: N� j � DATE: /0A 19 <br /> 1 <br /> , <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory- sealed in accordance with N1110.A.3. <br /> 3/24/2009 2:51 PM EnergyGauge® USA - FlaRes2008 <br /> Page 1 of 5 <br />