Laserfiche WebLink
FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1531 MARTINQUE 214 D pQ Builder Name: LENNAR <br /> Street: 3 74 b Aq/2-Pit yAr g.„ • Permit Office: C+ 2 - t p- I� <br /> City, State, Zip: TAMPA , FL , Permit Number: P 6 J <br /> Owner. LENNAR HOMES Jurisdiction: (, 11(DUD <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area <br /> a. Concrete Block - Int Insul, Exterior R =4.1 541.33 ft <br /> 2. Single family or multiple family Multi family <br /> 3. Number of units, if multiple family 1 b. N/A R= ft2 <br /> c. N/A R= ft2 <br /> 4. Number of Bedrooms 2 d. N/A R= ft2 <br /> 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area <br /> 6. Conditioned floor area (ft 1531 a. Under Attic (Vented) R =30.0 766.00 ft <br /> 7. Windows Description Area b. N/A R= k' <br /> a. U- Factor: Dbi, U =0.60 100.98 ft2 c. N/A R= <br /> SHGC: SHGC =0.32 11. Ducts <br /> b. U- Factor: Sgl, U =1.17 40.00 ft2 a. Sup: Attic Ret Attic AH: Interior Sup. R= 6, 355 ft <br /> SHGC: SHGC =0.74 12. Cooling systems <br /> c. U- Factor: N/A ft2 a. Central Unit <br /> SHGC: Cap: 34 kBtu/hr <br /> d. U- Factor: NIA k2 SEER: 14 <br /> SHGC: 13. Heating systems <br /> a. Electric Heat Pump Cap: 34 kBtu /hr <br /> e. U- Factor: N/A ft2 <br /> SHGC: HSPF: 8.2 <br /> 8. Floor Types Insulation Area 14. Hot water systems <br /> a. Slab -On -Grade Edge Insulation R =0.0 1531.00 ft' a. Electric Cap: 40 gallons <br /> b. Raised Floor R =19.0 88.00 ft <br /> c. N/A b. Conservation features EF: 0.92 <br /> R= ft <br /> None <br /> 15. Credits Pstat <br /> Glass /Floor Area: 0.092 Total As -Built Modified Loads: 30.94 PASS <br /> Total Baseline Loads: 38.54 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ,.•• 't gE S <br /> Code. calculation are in compliance with the Florida Energy specifications covered by this N∎ T. O • •.: <br /> calculation indicates compliance , h , ,, • ,P..��:, a _,� • with the Florida Energy Code. <r i ,,,,, ., ;,a . "'. � O <br /> \' <br /> PREPARED BY: <br /> �� Before construction is completed + �, ;� „ <br /> DATE: V this building will be inspected for 6 <br /> compliance with Section 553.908 p " <br /> y <br /> I hereby certify that this building, as designed •,i,: - . pliance Florida Statutes. •,� <br /> with the Florida Energy Code. ill / ....... <br /> � , ��v . <br /> y �. <br /> OWNER/AGENT: BUILDING OFE,IC L: '�� <br /> DATE: 41/01101%:// DATE: - i 0 <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory- sealed in accordance with N1110.A.3. <br /> 3/24/2009 2:51 PM EnergyGauge® USA - FlaRes2008 <br /> Page 1 of 5 <br />