Laserfiche WebLink
FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1531 SIESTA KEY 214 C Builder Name: LENNAR <br /> Street: Permit Office: <br /> City, State, Zip: TAMPA , FL , Permit Number: <br /> Owner: LENNAR HOMES Jurisdiction: <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area <br /> 2. Single family or multiple family Multi- family a. Concrete Block - Int Insul, Exterior R =4.1 541.33 ft <br /> b. N/A R= ft <br /> 3. Number of units, if multiple family 1 c. N/A R= ft <br /> 4. Number of Bedrooms 2 d. N/A R= ft2 <br /> 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area <br /> 6. Conditioned floor area (ft 1531 a. Under Attic (Vented) R =30.0 766.00 ft <br /> b. N/A R= ft <br /> 7. Windows Description Area c. N/A R= ft2 <br /> a. U- Factor: DbI, U =0.60 119.64 ft <br /> SHGC: SHGC =0.32 11. Ducts <br /> b. U- Factor. Sgl, U =1.17 33.33 ft2 a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 355 ft <br /> SHGC: SHGC =0.74 12. Cooling systems <br /> c. U- Factor. N/A ft a. Central Unit Cap: 34 kBtu/hr <br /> SHGC: SEER: 14 <br /> d. U- Factor: N/A ft2 13. Heating systems <br /> SHGC: a. Electric Heat Pump Cap: 34 kBtu/hr <br /> e. U- Factor: N/A ft2 <br /> HSPF: 8.2 <br /> SHGC: <br /> 14. Hot water systems <br /> 8. Floor Types Insulation Area a. Electric Cap: 40 gallons <br /> a. Slab -On -Grade Edge Insulation R =0.0 1531.00 ft2 p EF: 0.92 <br /> b. Raised Floor R =19.0 88.00 ft2 b. Conservation features <br /> c. N/A R= ft2 None <br /> 15. Credits Pstat <br /> Total As -Built Modified Loads: 30.62 PASS <br /> Glass /Floor Area: 0.100 Total Baseline Loads: 38.54 <br /> I hereby certify that the plans and specifications covered by Review of the plans and . ..• 0 ' .e '1 Srg <br /> this calculation are in compliance ' the Florida Energy specifications covered by this ti ,: ,' ___ ^ 0 .�. <br /> Code. calculation indicates compliance �� ,� ; : „s► <br /> ,, with the Florida Energy Code. . h h i,,, , , ** ` .; ° ; � p <br /> :; o V --- ` <br /> PREPARED BY: -- _ - ' -. <br /> . .,1_ <br /> DATE: Before building p construc <br /> inspected for <br /> WI psd : a compliance with Section 553.908 : <br /> *', d I hereby certify that t • uilding, as design .- d ' • mpliance Florida Statutes. wit the Florida Ener 9Y Code. /�� �'' F O <br /> / 1 , OD WB . OWNER/AGENT: BUILDING FFIC L: <br /> DATE: DATE: iol - v - e <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory- sealed in accordance with NI110.A.3. <br /> 3/24/2009 2:22 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5 <br />