Laserfiche WebLink
FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1371 ST CROIX 214 A N B Builder Name: LENNAR <br /> Street: 374 82 /MAN L/,) /44 . Permit Office: ell/ bo 2 f rip 4 <br /> City, State, Zip: TAMPA , FL , Permit Number. 9 B S L <br /> Owner: LENNAR Jurisdiction: 6 // odb <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area <br /> 2. Single family or multiple family Multi- family a. Concrete Block - Int Insul, Exterior R=4.1 998.67 ft <br /> b. N/A R= ft <br /> 3. Number of units, if multiple family 1 c N/A R= ft <br /> 4. Number of Bedrooms 3 d. N/A R= ft <br /> 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area <br /> 6. Conditioned floor area (ft 1371 a. Under Attic (Vented) R =30.0 686.00 ft <br /> b. N/A R= ft <br /> 7. Windows Description Area c. N/A R= ft <br /> a. U- Factor: Dbl, U =0.60 182.25 ft <br /> SHGC: SHGC =0.32 11. Ducts <br /> b. U- Factor: N/A ft2 a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 265 ft <br /> SHGC: 12. Cooling systems <br /> c. U- Factor: N/A ft a. Central Unit Cap: 28 kBtu/hr <br /> SHGC: SEER: 14 <br /> d. U- Factor: N/A ft2 13. Heating systems <br /> SHGC: a. Electric Heat Pump Cap: 28 kBtu/hr <br /> e. U- Factor: N/A ft2 HSPF:8.2 <br /> SHGC: <br /> 14. Hot water systems <br /> 8. Floor Types Insulation Area a. Electric Cap: 40 gallons <br /> a. Slab -On -Grade Edge Insulation R =0.0 1371.00 ft2 EF: 0.92 <br /> b. N/A R= ft2 b. Conservation features <br /> c. N/A R= ft2 None <br /> 15. Credits Pstat <br /> Total As -Built Modified Loads: 33.08 PASS <br /> Glass /Floor Area: 0.133 Total Baseline Loads: 40.16 <br /> I hereby certify that the plans and specifi covered by Review of the plans and " cations .' ' 1 E ST, •.,: <br /> this calculation are in compliance with the Florida Energy specifications covered by this N, .. ' .. O <br /> Code. ` C � calculation indicates compliance y '� „ 'f s .�� °s+` 40. with t he Florida Energy Code. e 1 . .... <br /> PREPARED B • 0.1_ l j � N:.,.. v:., • <br /> _ Before construction is completed c r� ` - - ti �_ <br /> h -n-- :a: <br /> DATE: this building will be inspected for ` : ; y <br /> compliance with Section 553.908 * ` ° . <br /> I hereby certify that this building, as designed, ' �' .• • -T. • c= Florida Statutes. �" ' <br /> with the Florida Energy Code. %G ' .�' <br /> w E..4 . <br /> OWNER/AGENT: A -I BUILDING OFFICIAL: t' /r J�,� <br /> DATE: "Wig % DATE:-f v7 <br /> , <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory- sealed in accordance with N1110.A.3. <br /> 3/24/2009 1:29 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5 <br />