Laserfiche WebLink
FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1371 ST CROIX 214 A N B Builder Name: LENNAR <br /> Street: Permit Office: <br /> City, State, Zip: TAMPA , FL , Permit Number: <br /> Owner: LENNAR Jurisdiction: <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area <br /> 2. Single family or multiple family Multi family a. Concrete Block - Int Insul, Exterior R =4.1 998.67 ft <br /> b. N/A R= ft <br /> 3. Number of units, if multiple family 1 c. N/A R= ft <br /> 4. Number of Bedrooms 3 d. N/A R= ft <br /> 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area <br /> 6. Conditioned floor area (ft 1371 a. Under Attic (Vented) R =30.0 686.00 ft <br /> b. N/A R= ft <br /> 7. Windows Description Area c. N/A R= ft <br /> a. U- Factor DbI, U =0.60 182.25 ft <br /> SHGC: SHGC =0.32 11. Ducts <br /> b. U- Factor: N/A ft2 a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 265 ft <br /> SHGC: 12. Cooling systems <br /> c. U- Factor. N/A ft a. Central Unit Cap: 28 kBtu /hr <br /> SHGC: SEER: 14 <br /> d. U- Factor. NIA ft2 13. Heating systems <br /> SHGC: a. Electric Heat Pump Cap: 28 kBtu/hr <br /> e. U- Factor: N/A ft2 HSPF:8.2 <br /> SHGC: <br /> 14. Hot water systems <br /> 8. Floor Types Insulation Area a. Electric Cap: 40 gallons <br /> a. Slab -On -Grade Edge Insulation R =0.0 1371.00 ft2 EF: 0.92 <br /> b. N/A R= ft b. Conservation features <br /> c. N/A R= ft2 None <br /> 15. Credits Pstat <br /> Total As -Built Modified Loads: 33.08 PASS <br /> Glass/Floor Area: 0.133 <br /> Total Baseline Loads: 40.16 <br /> I hereby certify that the plans and specifications covered by Review of the plans and : •'+ .F'f ......... <br /> KE S _ ?, II:' • <br /> this calculation are in compliance with the Florida Energy specifications covered by this : N, " ,, 0' <br /> Code. calculation indicates compliance / ; <br /> ,,,, ,s ;s+' <br /> ; <br /> - v with the Florida Energy Code. l r : rnrn:` - •, °, � 0 <br /> t ���. _ ..l t , <br /> PREPARED B Before construction is completed - yti - 0 <br /> will be inspected for ; �' .. <br /> 9 P it7. � ' ,. 'A'.: DATE: this building compliance with Section 553.908 .` ° �, <br /> I hereby certify that this building, as des - • , is compliance Florida Statutes. .': ' ' y� ` � <br /> with the Florida Energy Code. / ' j .•OD y �rg 0.... '' <br /> OWNER/AGENT: � / � / ; M BUILDI G OFFICIAL: %. <br /> DATE: r`r� DATE: �n/ q - 0 J � <br /> - Compliance requires certifica ion by the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory- sealed in accordance with N1110.A.3. <br /> 3/24/2009 1:29 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5 <br />