Laserfiche WebLink
AnchorWall (ver 4.00 Nov 2002) Page 2 of 6 <br /> Wachovia Bank @ Zephyr Commons, Pasco Cty, FL <br /> License: AW98011374 <br /> Friction <br /> Cohesion Angle Unit Weight <br /> Soil Data: Soil Description (pst) (degrees) (pct) <br /> Reinforced Soil: sand N/A 30.0 120.0 <br /> Retained Soil: sand N/A 30.0 120.0 <br /> Leveling Pad Soil: gravel N/A 40.0 140.0 <br /> Foundation Soil: sand 0.0 30.0 115.0 <br /> Anchor Wall Unit Name: Vertica (8 in) <br /> Properties Standard Units Cap Units <br /> Unit Height (in) 8.0 4.0 <br /> Unit Width (in) 11.5 10.0 <br /> Unit Length (in) 18.0 14.63 <br /> Setback (in) 0.562 NIA <br /> Weight (infilled) (lb) 125 42 <br /> Unit Weight (infilled) (pcf) 130.4 124.0 <br /> Center of Gravity (in) 5.75 5.0 <br /> Geosynthetic Reinforcement: NCMA Method <br /> Type Name Polymer Type Index Allowable <br /> ID No. Tensile Strength (1b/ft) <br /> (lb/ft) <br /> 1 Synteen SF 35 polyester 2627.0 866.7 <br /> Reduction Factors: NCMA Method <br /> Factor Synteen SF 35 <br /> Creep 1.67 <br /> Durability 1.10 <br /> Installation 1.10 <br /> Overall 1.50 <br /> • <br /> C: \Program Files\Anchor400\P- 6425 -#13 V.aws 17 Nov 2009 - 04:25:19 PM <br />