Laserfiche WebLink
Fastening #3: (steel) (Excludes use of Elastophene Flam 180 2.5 nun as base sheet.) Attach base sheet <br /> using SFS #15 High Load Fasteners or Soprafix(X) -EL fasteners and 70 mm Round Plates <br /> or Sopratix 2" Round Barbed Plates spaced 12" o.c. in a 5" wide heat welded lap. <br /> (Maxine m Design Pressure — 75 psf See Geteeal Llmilation #9) <br /> Fastening #4: (lightweight concrete, cenaentitious wood fiber, gypsum) Attach base sheet using TPR <br /> fasteners with Soprafix 2" Round Barbed Plates spaced 18" o.c. in a 4" wide heat welded <br /> or bituminous taped seam. <br /> (Mort Design Pressure — /S psf See Getreal Limitation #9) <br /> Fastening #5: (lightweight concrete, ccrnentitious wood fiber, gypsum) Attach base sheet using TPR <br /> fasteners with Soprafix 2" Round Barbed Plates spaced 24" o.c. in the center of the sheet <br /> Laps are heat welded. Fastener rows are stripped in with a 7" wide section of heat welded <br /> • base sheet membrane. <br /> (Maximum Design Pressure - 9S pap See General Lbriltatlon #9) <br /> Fastening #6: (gypsum) (Excludes the use of Elastophene Flam 180 2.5 mm as base sheet) Attach base <br /> sheet using ES Twin Loc-Nails spaced 9' o.c. in a 5" lap and 9" o.c. in one row in the <br /> center of the sheet. Laps are heat welded Fastener rows are stripped in with a 8" wide <br /> section of heat welded base sheet membrane. <br /> (Maximum Design Pressare - 60p40 See General Limitation #7) <br /> Fastening #7: (atee4 concrete) (Excludes the use of Elastophene Flam 180 2.5 ram as base sheet.) <br /> Attach base sheet using #14 Soprafix Fasteners and Soprafix 2" Round Barbed Plates <br /> spaced 12" o.c. in a 5" wide heat welded lap. <br /> (Maximum Design Pressure — 60 psf — See General Limitation #Z) <br /> • Note: Base sheet fasteners shaU be tested for withdrawal resistance in compliance with TAS 105 to confirm <br /> compliance with the wind load requirements with applicable Bonding Code. <br /> Ply Sheet (Optional) One ply of Elastophene Flam *, Elastophene Flam 2.2 *, Sopralene (180, 250 or <br /> 350) Flam *, or Sopralene (180, 250 or 350) SP, heat welded <br /> Or <br /> One ply of Sopralene Flam Stick* or Sopralene Stick, self adhered. (Note: Prime sanded <br /> surfaced Base Sheet.) <br /> *Requires heat welded cap membrane. <br /> Membrane: Elastophene SP 22mm *, Elastophene SP 3.0mm *, Elastophene Flam Glt, Elastophene Flam <br /> FR GR or FR+ GR, Elastophene Flam LS FR GR, Soprastar Flom, Sopralene (180, 250, <br /> 350) Flan GR, Sopralene (180, 250, 350) Flare FR OR or FR+ GR, UNILAY or Sopralast, <br /> heat welded <br /> Or <br /> Colphene FR GR, Colphene GR, or Colphene HR FR GR, self adhered. (Note: Prime <br /> sanded surfaced Base or Ply Sheet.) <br /> or <br /> Soprastar Stick, self - adhered to Elastocol 600c primed sand surfaced base or ply membrane <br /> *Require approved Surfacing. <br /> Surfacing: Surfircing is Optional on granular surfaced field cap membranes. <br /> Surfiacing is Required f r smooth or sanded surfaced field cap membranes. <br /> Refer to Underwriters Laboratories or intertek Testing Services listings for applicable fire <br /> classifications <br /> Apply any coating listed in Table 4 above, or any Miami -Dade approved coating system. <br /> Maaimum Design See Fastening Requirements above. <br /> Pressure: <br /> NOA No.: 07- 1217.07 <br /> ("IMO • Expiration Date: 03/01/11 <br /> Approval Date: 05/08/08 <br /> Page 50 of 78 <br />