Laserfiche WebLink
73077.02- 10947 <br /> Architectural Testing Page of 7 <br /> Test Specimen Description: (Continued) <br /> Weatherstripping: <br /> Description Quantity Location <br /> 0.187' backed by 0.230" high 1 Row Interior face of sill leg. Outer <br /> polypile with fin perimeter of stiles and exterior face <br /> of meeting rail on active sash. <br /> Inside of the interlock on the fixed <br /> meeting rail <br /> 0.187" backed by 0,270" high 1 Row Exterior face of stiles on the <br /> polypilc with fin active sash <br /> 3/8" diameter vinyl covered I Row Exterior face attic bottom rail on <br /> foam with fin the active sash <br /> Drainage: <br /> Description Quantity Location <br /> 1 /8" by 3/8" weephole 2 2 -3/4" from each end of sill <br /> 1/4" x 3/8" oval weephole 2 3" from each corner of the active <br /> sash under the bottom rail <br /> 1 -1/8" weepslot 2 Through each end of screen track <br /> on sill <br /> Hardware: <br /> Description Ouantity Location <br /> Metal lever locks with 2 8 -1/2" from each end of the lock <br /> adjacent keepers rail <br /> Vinyl tilt latches 2 Each end of the lock rail <br /> Block and tackle balance 2 One in each jamb <br /> Reinforcement: Steel reinforcement was utilized in the lock rail (see Drawing #51. -2821) <br /> and in the fixed meeting rail (see Drawing #51- 2919). <br /> c <br /> m•a '1190 QLe Q L M2S .Sn3 sdxaj dart 6T7:9T 6003- 60 -9Ed <br />