• <br /> Fastening #4: (Excludes use of Elastophene 180 Flam 2.5 mm as base sheet.) Attach base sheet using <br /> SFS Extra Load Fasteners HD or Soprafix (X] -EL fasteners and 70 mm Round Plates or <br /> Soprafix 2" Round Barbed Plates spaced 12" o.c. in a 5" wide heat welded lap. <br /> (Meets Maximums Design Pressure of -75 psf - See General Limitation #7.) <br /> Fastening #5: (Limited to use of Soprafix[X] and Sopralene Flam 250 Membranes only.) Attach base <br /> sheet using SFS Extra Load Fasteners HD or Soprafix [X] -EL fasteners and 70 mm Round <br /> Plates spaced 12" o.c. in a 6" wide heat welded lap. <br /> (Mere Maximum Design Pressure of -97.S psf- See General Lbnilatlon #7.) <br /> Fastening #6: (Excludes the use of Elastophene 180 Flam 2.5 mm as base sheet.) Attach base sheet using <br /> #14 Soprafix Fasteners and Soprafix 2" Round Barbed Plates spaced 12" o.c. in a 5" wide <br /> heat welded lap. <br /> (Meet Maximum Design Pressure of-60 psf - See General Limitation #7.) <br /> Ply Sheet: (Optional) One or more plies of Elastophene Flamm, Elastophene Flam 2.2 *, Sopralene <br /> (180, 250 or 350) Flam *, or Sopralene (180, 250 or 350) SP, heat welded <br /> Or <br /> One ply of Sopralene Flam Stick *, Sopralene Stick or EPS Firm Stick *, self adhered. <br /> (Note: Prime sanded surfaced Base Sheet, not allowed on film surficed membranes.) <br /> *Requires heat welded cap membrane. <br /> Membrane: Elastophene Flam GR, Elastophene Flam FR GR or FR+ GR, Elastophene Flam LS FR <br /> GR, Soprastar Flam, Sopralene (180, 250, 350) Flam GR, Sopralene (180, 250, 350) Flam <br /> FR GR or FR+ GR or Sopralast, heat welded <br /> Or <br /> Colphene FR GR, Colphene GR or Colphene HR FR GR self adhered. (Note: Prime <br /> sanded surfaced Base or Ply Sheet, not permitted on film surfaced membranes.) <br /> Or <br /> Soprastar Stick, self - adhered to Elastocol 600c primed sand surfaced base or ply <br /> membrane <br /> Surfacing: Surfacing is Optional on granular surfaced field cap membranes. <br /> Surfacing is Required for smooth or sanded surfaced field cap membranes. <br /> Refer to Underwriters Laboratories or Intertek Testing Services listings for <br /> applicable fire classifications <br /> Apply any coating listed in Table 4 above, or any Miami -Dade approved coating <br /> systems. <br /> Maximum Design <br /> Pressure: See Fastening Requirements above. <br /> NOA No.: 07- 1217.06 <br /> MID Expiration Date: 03/01/11 <br /> Approval Date: 04x24/08 <br /> Page 44 of 55 <br /> .I <br />