Laserfiche WebLink
L. Roberto Lomas P.E. Engineering Evaluation Report <br /> 1432 Woodford Rd. <br /> Clemmons, NC 27012 Report No.: 510848 <br /> 336 - 945 -9695 <br /> Manufacturer: Alenco Windows <br /> 615 Carson St <br /> Bryan, Texas 77801 <br /> Product Line: 4710FLIR Aluminum Single Hung Window— Large Missile Impact <br /> Compliance: <br /> The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of <br /> Community Affairs for Statewide Acceptance per Rule 9B- 72.070 method 1(d). The product listed herein complies with <br /> the 2007 Florida Building Code. <br /> Product description: 4710FLIR Single Hung Aluminum Window. Frame made of extruded aluminum 6063 -T5. Frame is <br /> of double -screw butt-type corner construction. <br /> Supporting Technical Documentation: <br /> 1. Approval document: drawing number FL 00532, dated 6/18/08 sheet 1 of 3, titled 4710FLIR Aluminum Single <br /> Hung Window, prepared, signed and sealed by L. Roberto Lomas P.E. <br /> 2. Test Report No.: CCLI — 08- 089, signed Brandon Newman and Wesley A. Wilson <br /> Construction Consulting Laboratory, International <br /> Carrolton, TX <br /> AAMA/NWWDA 101/I.S.2 -97 <br /> Uniform Load Structural +50psf / -60psf Design pressure <br /> Water penetration resistance: 6.0psf <br /> ASTM E1886 -05 and ASTM E1996 -05 <br /> ASTM E1886/ E1996 Large Missile Impact Test, Level D, Wind Zone 3 <br /> ASTM E1886/ E1996 Cyclic Load Test, +50psf / -57psf design pressure <br /> 3. Anchor calculations, report number 510849, prepared, signed and sealed by L. Roberto Lomas P.E. <br /> Limitations and Conditions of use: <br /> • Maximum design pressure: +40.0 psf /- 57.0psf <br /> • Maximum unit size: 53 "x72" <br /> • Units must be glazed with 7/8" IGU consisting of 1/8° Annealed interior lite — air — laminated exterior lite <br /> consisting of 1/8" Ann - .090" Solutia Saflex interlayer -1/8" Annealed per ASTM E 1300 <br /> • This product is not rated to be used in the HVHZ. <br /> • This product is impact resistant and does not require impact protection in wind -borne debris regions. <br /> • Frame material to be extruded aluminum 6063 -T5. <br /> • Solutia Saflex per N.O.A. 03- 0827.08 <br /> Installation: <br /> • Units must be installed in accordance with approval document, FL 00532. <br /> Certification of Independence: <br /> Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the <br /> product(s) for which this report is being issued. Also, I don't have nor will acquire a financial interest in any other entity <br /> involved in the approval process of the listed product(s). <br /> ‘: 0111111/1 0 / <br /> \`' • R. L • � ��i <br /> J . k, q <br /> • <br /> -0 • TAT O F ;• <br /> Fs : 0 RIDQ: •G \: <br /> i //, ONAL -, \\ <br /> 1 of 1 Luis R. Lomas, P.E. <br /> FL No.: 62514 <br /> 06/18/2008 <br />