My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10082
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10082
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2011 9:01:16 AM
Creation date
1/27/2011 9:01:13 AM
Metadata
Fields
Template:
Building Department
Company Name
EMERALD POINTE RV RESORT
Building Department - Doc Type
Permit
Permit #
10-10082
Building Department - Name
EMERALD POINT RV
Address
39602 AMETHYST WAY LOT 5
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM DESCRIPTION <br /> SYSTEM A - Advantagelok II Metal Panel <br /> Deck Type: Wood, Non - insulated <br /> Deck Description: 19 / 32 " or greater plywood or wood plank. <br /> Slope Range: 2 ": 12" or greater <br /> Maximum Uplift See Table A below <br /> Pressure: <br /> Deck Attachment: In accordance with applicable Building Code, but in no case it shall be less <br /> than #8d ring shank roofing nails spaced at 6" o. c. <br /> Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a <br /> minimum 4" side -laps and 6" end -laps. Underlayment shall be fastened with <br /> corrosion resistant tin -caps and 1 annular ring -shank nails, spaced 6" o.c. at <br /> all laps and two staggered rows 12" o.c. in the field of the roll. <br /> Valleys: Valley construction shall be in compliance with Roofing Application Standard <br /> RAS 133 and with Union Corrugating Company's current published <br /> installation instructions. <br /> Fire Barrier Board: Any approved fire barrier having an NOA. Or for class A or B fire rating, <br /> install minimum 1/4" thick Georgia Pacific "Dens Deck" (with current NOA) or <br /> minimum 4mm thick of Tritex, RockRoof (with current NOA) or 5 /8" water <br /> • resistant type X gypsum sheathing with treated core and facer, or one layer of <br /> Elk Corporation Versashield (with current NOA). <br /> Metal Panels and Install the " AdvantageLok II Metal Roofing Panel" and accessories in <br /> Accessories: compliance with Union Corrugating Company's current published installation <br /> instructions and details. Flashing, penetrations, valley construction and other <br /> details shall be constructed in compliance with the minimum requirements <br /> provided in Roofing Application Standards RAS 133. <br /> AdvantageLok II Metal Roofing Panels shall be fastened with a minimum of <br /> #10 -12 x 1" A -point pancake head corrosion resistant fasteners. Fasteners shall <br /> of sufficient length to penetrate through the sheathing a minimum of /16 <br /> 1. Fasteners shall be placed 6" o.c. as shown in Detail B. See Table A <br /> below for maximum pressures allowed. <br /> 2. For Perimeter and Corners, use a 3/16" bead of SikFlex 201 Sealant as <br /> shown in Detail C. See Table A below for maximum pressures allowed. <br /> TABLE A <br /> Maximum Design Pressure <br /> Field Perimeter and Corner <br /> Maximum Design Pressure -61.1 psf - 108.15 psf <br /> 1. Extrapolation shall not be allowed <br /> 2. Using 3/16" bead of SikFlex 201 Sealant as shown in Detail C. <br /> NOA No.: 06- 1002.15 <br /> = r <br /> Expiration Date: 12/07/11 <br /> Approval Date: 12/07/06 <br /> ���NT� Page 3 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.