Laserfiche WebLink
' \J i <br /> TRINITY ERD <br /> 4. PRODUCT DESCRIPTION: <br /> 4.1 GlassMaster 25, StormMaster Slate and Chalet are fiberglass reinforced, 3 -tab asphalt roof <br /> shingles. <br /> 4.2 Stratford Is a fiberglass reinforced, non - laminated architectural roof shingle where the <br /> dimensional appearance is established through a granule overlay feature. <br /> 4,3 Pinnacle 35 and StormMaster LM are fiberglass reinforced, laminated asphalt roof shingles. <br /> 5. LIMITATIONS: <br /> 5.1 Fire Classification Is not part of this Evaluation Report; refer to current Approved Roofing <br /> Materials Directory for fire ratings of thls product. <br /> 5.2 Wind Classification (non- HVHZ): <br /> 5.2.1 All Atlas shingles noted herein are Classified in accordance with FBC Table 1504.1.2 to ASTM <br /> D6381, Class H and PBC Tables 1507.2.10 and 8905.2.6.1 to ASTM D3161, Class F and <br /> ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to <br /> 150 mph. Refer to Section 6 for installation requirements to meet this wind rating. <br /> 5,2,2 Classification by this method applies to buildings less than 60 feet high and with Wind <br /> Exposure B and C only in an Occupancy Category of I or TI. <br /> 5,2.3 F ^r buildings falling outside the constraints in 5,2.1 or 5.2.2, calculations by a qualified <br /> design Nrofessfonal in accordance. with UL2390 ! ASTM D7158 ! ASCE 7 may e conducted <br /> or :he sp °cific ;inject with data `er :he soe'.fic _ningl=. ; ?eference; =?C '509,_:, Contact <br /> the shingle rnarufacturer : "or dan sce_ific cc each £nlr:;;?, <br /> �.3 Wind Resistance iHVH ; <br /> 5.3.1 Shall not be Installed on roof mean heights in excess of 33 feet. <br /> 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the <br /> Florida Building Code and F.A.C. Rule 9B -72, <br /> 6. INSTALLATION: <br /> 6.1 Non -HVHZ: <br /> 6.1.1 Underlayment: <br /> 6.1.1.1 Underlayment shall be acceptable to Atlas Roofing Corporation and shall hold current FBC <br /> Approval, or be Locally Approved per Rule 98 -72, per FBC Sections 1507.2.3 and /or 1507.2.4. <br /> 6.1.2 Asphalt Shingles: <br /> • <br /> 6.1.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published <br /> instructions, but not less than four (4) fasteners per shingle In accordance with the <br /> requirements of FBC Section 1507.2 or FBC Residential Volume Section R905.2. <br /> 6.1.2.2 Fasteners and fastener placement shall be In accordance with manufacturer's current <br /> published installation instructions. <br /> 6.1.2.3 Where the roof slope exceeds 20 units vertical In 12 units horizontal (166 - percent sfope), <br /> special methods of fastening are required. <br /> Exterior Research and Design, LLC. Evaluation Report Al2620.12.08 <br /> Certificate orAutlioriarehon *9509 <br /> Pt9T92 -R1 <br /> Date of Issuance: 12/18/2008 <br /> Page 3 of 5 <br />