G310A -A <br /> Revised February 20, 2007 Page 7 <br /> ACCESSORIES <br /> Remote Alarm (P/N c311 -A) Manual Remote Pull Station (G309 -A) <br /> DESCRIPTION: DESCRIPTION: <br /> Due to different designs of cabinets, different A manual remote pull station is available where local • <br /> materials and thicknesses, the sonic signal from the fire codes or circumstances require the capability to <br /> CPU board can in some cases be attenuated to a db manually activate the range top extinguisher system. <br /> (loudness) level that will not activate the shutoff of the See FIGURE 7 below. <br /> power supply to a range. If this is the case, an <br /> optional external remote alarm is available to help f ,- <br /> maintain the higher db (loudness) level to optimize the ' ,~ <br /> operation of the electric/gas shutoff for the stove. , L., -- <br /> L PULL <br /> "∎ <br /> 48" (4 Ft.) C � • <br /> t , c: ;; FIGURE 7 <br /> t : <br /> <, „ Manual activation of the system will cause the <br /> ,`, >r extinguisher unit to fully discharge extinguishing <br /> agent, shut off the range top burners and activate the • <br /> alarm or other electrical accessory. Once activated, <br /> the automatic sequence cannot be interrupted. <br /> FIGURE 5 The manual pull station is installed at a height not <br /> exceeding 60" from the floor and should be located in <br /> the path of exit. Avoid locating the manual pull station <br /> Installation: where the occupant would have to reach over the <br /> If the remote alarm is required, perform the following range top- cooking element to activate the system. <br /> installation steps. (Some jurisdictions require certain distances.) <br /> • Mount the remote alarm in a convenient location <br /> above the stove on the underside of the range NOTE: An Identification sign shall be installed <br /> hood or cabinet. indicating "NOT BUILDING FIRE ALARM PULL <br /> • Feed the cable wire through the access hole into STATION." <br /> the system enclosure. Installation: <br /> • Position the cable wire on the same side of the <br /> Cylinder as the sensor wires. • Determine the best location for the manual pull station. <br /> • Connect the cable wire connector to location "P2" The location must be accessible as required. <br /> designation on the CPU board. (See FIGURE 6) • Install cable in conduit or attach using cable clamps as <br /> below. required by jurisdiction. <br /> • Verify that external alarm is working during • Feed the cable wire through the access hole into the <br /> system checkout. system enclosure. <br /> • Position the cable wire on the same side of the cylinder <br /> : ;— "t as the sensor wires. <br /> "3 t 3 1 ▪ Connect (overlap sensor terminals) the cable wire <br /> — --- spade terminals to location "P1 -3 & 4" designation on <br /> w Main CPU. (See FIGURE 8) below. No polarity <br /> +1t� -� <br /> �f - required on wires. <br /> t 1 ` "'j • Verify that manual remote pull station is working during <br /> i <br /> ' * system checkout. <br /> i Uli •nn ye I r0 . ' • --- _ - <br /> _ t <br /> FIGURE 6 i � _� QOi i Il FIGURE 8 ........„,z � puu <br /> 0 I <br /> t <br /> 360" (30Ft.) <br />