My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10233
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10233
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2011 1:54:25 PM
Creation date
1/27/2011 1:54:21 PM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA HOSPITAL OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
10-10233
Building Department - Name
FLORIDA HOSPITAL OF ZEPHYRHILLS
Address
7050 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
G310A -A <br /> Page 12 Revised February 20, 2007 <br /> r <br /> VALVE <br /> GAS FLOW : RESET : POWER INTERCONNECT CABLE IS <br /> INDICATOR , RESET STANDARD CONFIGURATION <br /> a. ? TO MAIN CPU <br /> OPTIONAL ►f' (SEE FIGURE 3) <br /> ALARM /STROBE <br /> (SEE FIGURE 10) i y' 4 <br /> r i . ? o o 00 I <br /> POWER CORD ■ fit _ ` _� <br /> FROM RANGE <br /> \4 <br /> ` � umaw� <br /> .E ._._ ~s , zwn <br /> PLUG POWER CORD = -177-7,1- <br /> INTO WALL OUTLET i 4 r <br /> 1= <br /> + , u , <br /> • <br /> GAS SHUTOFF CONTROL BOX SONIC RECEIVER ASSEMBLY <br /> INSTALLATION (Continued) - 1 (OPTIONAL -SEE FIGURE 9) <br /> t , <br /> See FIGURE 18 for the following steps: <br /> 4. Plug the valve into the connector on the Gas ' OPTIONAL INTERFACE ENCLOSURE 1 <br /> Shutoff Control Box. : ASSEMBLY (SEE FIGURE 11) <br /> ■ <br /> 5. Connect the interconnect cable or Optional <br /> Receiver Board into the Gas Shutoff Control FIGURE 18 <br /> Box. <br /> 6. If Interconnect Cable is used, route the cable <br /> from Gas Shutoff Control Box to the Main CPU Arming/ Resetting Gas Shutoff Assembly <br /> board. Spade lugs on the interconnect cable <br /> connect to terminal strip P1 -5 & 7 of the Main <br /> 'U board. (See FIGURE 3 page 5) 1 Turn power "ON" to the stove. <br /> Hug the power cord from the stove into the Gas <br /> Shutoff Control Box and then the power cord for CAUTION: "GAS WILL BE FLOWING TO <br /> the Gas Shutoff Box into the wall outlet. THE STOVE WHEN PERFORMING THE NEXT <br /> STEP" <br /> SONIC GAS SHUTOFF 2. The "Gas Flow" indicator light should be lit. If <br /> Description: not, push the "Power Reset" switch ( first) and <br /> then the "Valve Reset" switch (second) to arm <br /> To convert the standard shutoff to a remote the control box. <br /> sonic version, the standard interface cable is <br /> replaced with the Sonic Receiver Assembly. Note: In the event that the gas shutoff is <br /> Typical interface is interchangeable for both the activated or an interruption in power occurs, it <br /> interconnect cable and the Sonic Receiver must be reset. <br /> board. Either interface connection plugs into the See System Checkout Procedures on Page 16 & 17 <br /> electric shutoff, depending on which interface <br /> option is chosen. In some cases a sonic <br /> version of the shutoff device may be required. If <br /> this is the case, the audible alarm is required to <br /> shut off the stove via the optional Sonic <br /> Receiver Board. (See FIGURE 9) <br />
The URL can be used to link to this page
Your browser does not support the video tag.