My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10233
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10233
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2011 1:54:25 PM
Creation date
1/27/2011 1:54:21 PM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA HOSPITAL OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
10-10233
Building Department - Name
FLORIDA HOSPITAL OF ZEPHYRHILLS
Address
7050 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
G310A -A <br /> Page 16 Revised February 20, 2007 <br /> SYSTEM CHECK OUT <br /> SYSTEM CHECK -OUT AFTER INSTALLATION Use a wire and create a short across one of the <br /> sensor terminals (P1 -1 & 2 or P1 -3 & 4). <br /> CAUTION: To avoid accidental discharge <br /> "DO NOT REMOVE PULL PIN" at this time IMPORTANT: REMAIN SHORTED FOR 20 - 30 <br /> Refer to Page 17, FIGURE 26 for this step AFTER SECONDS. <br /> system and shutoff check-out. 1. Verify that the release valve solenoid is activated. <br /> After aiming the spray nozzles and placement of the (See FIGURE 26) <br /> temperature sensors conduct final system check -out <br /> to include operation of the electric or gas shutoff by 2. After 20 — 30 seconds, remove the short across the <br /> accomplishing the following: sensor terminals. System alarm continues (Fire <br /> Detect Mode Disabled). Push K1 switch near LED <br /> 1. Insure the 9V DC battery is installed in the central on Main CPU board for Piezo alarm reset. <br /> (See FIGURE 3 ) <br /> processing unit (CPU) board. <br /> 2. If the alarm sounds, remove the battery 3. Verify that the electric or gas shutoff has been <br /> immediately and recheck the connections as activated by observing the test results. <br /> shown in FIGURE 3 for one or more of the See "TEST RESULTS" below. <br /> following: <br /> A. Open or bad connection to the sensors SONIC RECEIVER TEST PROCEDURES <br /> B. Shorted sensor or frayed wires shorting. <br /> C. Open or bad connection to the electronic <br /> release valve. (IF THE INTERCONNECT CABLE IS USED GO TO <br /> 3. In the event of a low battery, the alarm will "chirp" "INTERCONNECT TEST PROCEDURES ") <br /> approximately once every 45 seconds. The unit is <br /> still operational, but the battery must be replaced to Insure the electric or gas shutoff has been installed in <br /> assure continued, uninterrupted operation. accordance with the instruction contained in this <br /> manual. See Page 10 for Electric Range and Page 11 <br /> SHUTOFF CHECK -OUT & 12 for Gas Range. See page 8 for Sonic Receiver <br /> details. <br /> INTERCONNECT CABLE TEST PROCEDURES <br /> Perform the following: <br /> (IF OPTIONAL SONIC RECEIVER IS USED GO TO "SONIC <br /> RECEIVER" TEST PROCEDURES) Sonic Receiver: Install unit and plug into shutoff. <br /> Verify that LED "Power On" light is on. <br /> Insure the electric or gas shutoff has been installed in <br /> accordance with the instruction contained in this Electric Stove: Turn on any burner to the high <br /> manual. See Page 9 &10 for Electric Range and Page position until burner coil is hot. <br /> 11 & 12 for Gas Range. <br /> For Gas Stove: Light any burner and turn to the <br /> Perform the following: high position. <br /> Electric Stove: Turn on any burner to the high 1. Locate and remove the positive ( +) #2 heat sensor <br /> position until burner coil is hot. terminal wire connection (red lug) on the central <br /> processing unit control board terminal block. SEE <br /> For Gas Stove: Light any burner and turn to the FIGURE 3. <br /> high position. 2. Once removed, the audible Piezo Alarm on the <br /> Main CPU control board will activate. <br /> Note: DO NOT REMOVE a sensor wire. This NOTE: "Fail Safe Mode" is initiated. Though the <br /> enables the "FAIL SAFE" mode. Sensor audible alarm has activated, extinguisher cylinder <br /> must have a short across the terminals to release valve will not activate. <br /> simulate a "FIRE DETECT MODE ". 3. Allow Main CPU board audible alarm to sound for <br /> approximately 20 -30 seconds, which will activate <br /> either the electric or gas shutoff via the Sonic <br /> Receiver board. <br />
The URL can be used to link to this page
Your browser does not support the video tag.