My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10321
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10321
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/28/2011 10:56:48 AM
Creation date
1/28/2011 10:56:43 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
10-10321
Building Department - Name
KOB PROPERTIES LLC
Address
7813 7833 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AES 7788 Series RF Subset ibex Unit -- Installation and Operation Manual <br /> Power Requirements: 16.5 VAC, 40VA; <br /> • For UL certificated burglar alarm installations, use the Listed AMSECO transformer <br /> p/n XF1640 <br /> • For commercial fire alarm installations in the U.S., use the Listed AMSECO <br /> transformer p/n XF 1640.. <br /> • Do Not Connect To A Receptacle Controlled By A Switch <br /> Backup Battery requirement, Commercial Fire <br /> • Central Station Fire Signaling (24hr): use a 12V, 73 AH battery <br /> • Remote Station Fire Signaling (24hr): use a 12V, 7.5 AH battery <br /> UL 681: <br /> • Commercial Burglar Alarm Installation (4hr) use 12V, 7.5 AH battery <br /> • Replace battery(s) every 3 years <br /> UL 1610: <br /> • For Burglar Alarm installations the 7788F unit shall be connected to a UL Listed <br /> central control panel such that opening and closing signals are provided. <br /> 7788F EOL Inputs / Zones: <br /> • EOL Alarm Inputs must be programmed for Supervised or Fire. <br /> • For RF Type 6 Fire Alarm Systems, and Central <br /> Station Burglar Alarm Systems - connect the J4 x <br /> output of the 7788 Subscriber Unit circuit board to a �` <br /> trouble zone on an FACP or some other method to I <br /> tit 0 <br /> annunciate the trouble at the premise. Refer to pages 14 <br /> & 15 for J4's location and additional information. <br /> Unsupervised. Contact rating 24 VDC, I -Amp resistive maximum. <br /> The wire connections between the control panel and J4 output must be supervised <br /> against opens, shorts and grounds <br /> • For UL installations, the wire linking alarm panel must use electrically supervised <br /> inputs (program the subscriber unit for Supervised or Fire Supervised accordingly) <br /> AES Corporation 10 40 -7788. Reis 3a. 4/9/2009 <br />
The URL can be used to link to this page
Your browser does not support the video tag.