My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10387
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10387
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2011 8:11:53 AM
Creation date
1/31/2011 8:11:47 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
10-10387
Building Department - Name
BOLENDER INVESTMENTS INC
Address
4918 AIRPORT RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Chapter 3 - System Design <br /> Page 3 -2 <br /> REV. 3 <br /> d. Piping Requirements: e. Nozzle Placement: <br /> Piping diagrams include limitations on pipe length and fit- The nozzle is to be mounted in the center (See Note) of the <br /> tings. See the following pages for specific piping design and protected area, with the discharge holes in the nozzle no <br /> limitations for each size cylinder. greater than six (6) inches from the ceiling. For duct protec- <br /> tion, the nozzle is to be mounted in the center. See Figure <br /> ►Note: All listed piping diagrams represent maximum number 3 -1. <br /> of nozzles allowed. In applications that do not require the <br /> maximum number of nozzles, the quantity of nozzles can be <br /> reduced. <br /> In applications of this type, along with the already listed lim- <br /> itations (notes included with each maximum layout), the fol- <br /> lowing limitations apply: <br /> • On the reduced nozzle side of the piping layout, the <br /> largest listed size pipe on the standard configuration lay- Height <br /> out must be utilized from T1 to nozzle. <br /> • The maximum length of the reduced nozzle side must be <br /> the original combination from T1 to T2, and T2 to nozzle. <br /> Note: In systems utilizing a T3 split, the maximum length 1 <br /> of the reduced nozzle side must be the original combina \ <br /> tion from T1 to T2, T2 to T3, and T3 to nozzle. <br /> • The maximum number of elbows must be the original Side1 Side <br /> combiantion from T1 to T2, and T2 to nozzle. Note: In <br /> systems utilizing a T3 split, the maximum number of <br /> elbows must be the original combination from T1 to T2, T2 Figure 3 -1. Nozzle Location <br /> • to T3, and T3 to nozzle. 4 02866°° <br /> Note: See Design Chart for allowable offset of nozzles from <br /> center of each hazard area. <br /> f. Nozzle Coverages: <br /> Protection <br /> Zone /Nozzle Specifications Nozzle Location within Nozzle Nozzle <br /> Protection Nozzle L W Ht Maximum Protection Zone Offset** Orientation <br /> ► Screening N -SCR — 8 ft. 12 ft. Side 8 ft. (2.4 m) Length - Center 0 - 6 in. Vertical <br /> (2.5 m) (3.7 m) Width - Center <br /> Work Area N -OTF 8 ft. 8 ft. 12 ft. Area 64 sq ft Length - Center 0 - 6 in. Vertical <br /> (2.4 m) (2.4 m) (3.7 m) (5.9 sq. m) Width - Center <br /> Side 8 ft. (2.4 m) <br /> Plenum N -PLU 4 ft. 8 ft. 12 ft. Area 32 sq ft Length - Center 0 - 6 in. Vertical <br /> (1.2 m) (2.4 m) (3.7 m) (3 sq. m) Width - Center <br /> Side 8 ft. (2.4 m) <br /> Exhaust N -DCT 12 ft. (3.7 m) Perimeter or Length - Center 0 - 6 in. Vertical <br /> Duct* 3 ft. -10 in. (1.2 m) Dia. Width - Center (up) <br /> 24 ft. (7.3 m) Length <br /> * Single nozzle application on a PCI -15ABC or two nozzle application on a PCI- 25sABC only. <br /> ** Nozzle offset is the maximum distance from the tip of the nozzle and the closest edge of the protection zone. <br /> ULEX 3437 CEx732 <br /> September 1, 2006 <br />
The URL can be used to link to this page
Your browser does not support the video tag.