Laserfiche WebLink
QUICK SELECTOR FOR FIRE AND SOUND RATED SYSTEMS <br /> Gypsum Plaster Fireproofing Colman: (18WF4S or heavier) (CAD FlLE NAME Gomm OR GOIDe.DxF) <br /> No. Fire Rating Ref. Design No. Description STC Tbat No. <br /> 1 1 hr. BMS 92 -Table 40 3/4' 1(9.0 mm) gypsum plaster, 1:3 sand scratch, 1:3 None None <br /> GA CM 1300 sand brarm on metal lath. <br /> 2 2 hr. life UL X402 1" (25.4 mm) gypsum plaster, 100:2 partite scratch, None None <br /> GA CM 2320 100:3 perlite brown, on self- furring Iath. <br /> 3 3 hr. o UL X402 1 3/6' (34.9 mm) gypsum plaster, 100:2 perlite scratch, None None <br /> - GA CM 3310 100:3 perlite brown, on self- furring Iath. <br /> 4 4 hr. w,— UL X402 1 3/4' (44.5 mm) gypsum plaster, 100:2 perlite scratch, None None <br /> GA CM 4410 100:3 perlite brown, on self- furring Iath. <br /> Gypsum Plaster Fireproofing Beams (8WF24 or heavier) (CAD FILE NAME GoLDC.DwG on GOLDC.DXF) <br /> 1 2 hr. Kagrinmauganiamx UL R4197 -1 1 1/8' (28.6 mm) gypsum plaster, 100 perlite scratch None None <br /> milinemameit GA BM 2221 coat, 100:21/2 perlite brown coat on self - furring lath. <br /> 2 3 hr. UL R4197 -1 1 1/4' (38.1 mm) gptwn plaster, 100:2 1/2 perlite scratch None None <br /> monenommen GA BM 3110 coat, 100:2 1/2 perlite brown coat on self- furring lath. <br /> 1 1 <br /> Veneer Plaster Partitions -Wood Framing (CAD FILE NAME GDLDD.DWG OR GoLDO.DxF) <br /> No. Fire Rating Ref. Design No. Description STC Teat No. <br /> SINGLE LAYER <br /> 1 1 hr. U. of Cal. E.S. 6727 3/32' (2.4 mm) Veneer Plaster applied to 1/2' (12.7 mm) 34 NGC 2161 <br /> Fire - Shield C Kal -Kore nailed to both sides of wood studs <br /> 16" o.c. (406 mm). <br /> Veneer Plaster Partitions -Steel Framing (coo FILE NAME GoLDE.Dwc oR GOLDE.DxF) <br /> SINGLE LAVER — 21/2' (63.5 mm) STUDS <br /> 1 1M. U. of Cal. E.S. 6892 3/32' (2.4 mm) Veneer Plaster applied to 1/2' (12.7 mm) 42 est. <br /> • ! ... Fire- Shield C Kai -Kore on both sides of 21/2'63.5 mm) <br /> steel studs 24` o.c. (610 mm) with 1' (25.4 mm) screws <br /> 12' o.c. (144 mm) and 9' o.c. (229 mm) along edges. <br /> Studs 16 o.c. (406 mm) preferred method. <br /> For additional Kal -Kore Fire and Sound rated systems reference gypsum wallboard systems. <br /> Gypsum Wallboard Partitions -Wood Framing (toad - bearing) (CAD FILE NAME GOL)H.DWG OR GOLDH.DXF) <br /> No. Fire Rating Ref. Design No. Description STC Test No. <br /> SINGLE LAYER <br /> FIRE – SOUND <br /> 1 45 min. U L U317 1/2` (12.7 mm) Fire - Shield C Gypsum Wallboard or 1/2' 34 NGC 2161 <br /> (12.7 mm) Fire- Shield C Kal -Kore plaster base nailed both <br /> sides 2 x 4 (38 mm x 89 mm) studs, 16' o.c. (406 mm). <br /> 2 1 hr. il=== UL U305 5/8' (15.9 mm) Fire - Shield Gypsum Wallboard, 5/8' (15.9 mm) 35 NGC 2403 <br /> GA WP 3605 Fire - Shield Kal -Kore plaster base or 5/8' (15.9 mm) Fire- Shield <br /> MR Board nailed both sides 2 x 4 (38 mm x 89 mm) <br /> wood studs, 16' o.c. (406 mm). <br /> 10 NATIONAL GYPSUM QUICK SELECTOR/GENERAL REFERENCE <br />