My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10427
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10427
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2011 8:49:52 AM
Creation date
2/1/2011 8:49:49 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
10-10427
Building Department - Name
S AND M LLC
Address
38424 5TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Print Date: 4/1/2010 2:43:21PM <br /> :$PNYAMII� � :t �,�.� �` � ,. � � � � I� �.�� 13� , � 1 t � aa'� �� ;3s I '� ,,, i 1i <br /> F Commercial Activity Date: 4/1/2010 1:05:30PM <br /> t ; 5 <br /> R .f' C <br /> e , , Zephyrhills Fire Rescue ctivity Number: 1-171-10-0342 <br /> FLORIDA <br /> , Fire Prevention Bureau Activity Cause: Request <br /> 6907 Dairy Rd Inspector Name. Hector Noyes <br /> Zephyrhills, FL 33542 <br /> Inspector Phone: <br /> Phone: 813 -780 -0041 p <br /> Fax: 813- 780 -0044 <br /> Party: Occupancy Type: Mercantile <br /> Judy's Boutigue & Consignment Property Use: Specialty Shop <br /> (000578) Total Violation: 0 <br /> 38424 5TH AVE Corrected Violation: 0 <br /> ZEPHYRHILLS, FL 33542 Hours: 1.17 <br /> Total Fees: $ 0.00 <br /> erg .. 5 •. �! �i zs , ` , .,' r 3 E - 3 � # � i <br /> 1 Ref. Number: NFPA101 (2006) Florida Fire Prevention (2007) 36.2.4.3 Number of Exits. <br /> A single means of egress shall be permitted in a Class C mercantile occupancy, provided that the travel distance to the exit or to a mall does not exceed <br /> 23 m (75 ft). <br /> 2 Ref. Number: NFPA101 (2006) Florida Fire Prevention (2007) 36.3.5.3 Extinguishment Requirements. <br /> Portable fire extinguishers shall be provided in all mercantile occupancies in accordance with 9.7.4.1. <br /> Comment: 2A -10 BC shall be provided <br /> 3 Ref. Number: NFPA 1 (2006) Florida Fire Prevention (2007) 10.10.1 Smoking. <br /> Where smoking is considered a fire hazard, the AHJ shall be authorized to order the owner in writing to post "No Smoking" signs in conspicuous, <br /> designated locations where smoking is prohibited. <br /> Comment: No Smoking signs shall be posted. <br /> 4 Ref. Number: NFPA 1 (2006) Florida Fire Prevention (2007) 10.19.6 Attic, Under - Floor, and Concealed Spaces. <br /> Attic, under -floor, and concealed spaces used for storage of combustible materials shall comply with the protection from hazards requirements for <br /> storage rooms in NFPA 101. <br /> 5 Ref. Number: NFPA 1 (2006) Florida Fire Prevention (2007) 10.19.3.1 Ceiling Clearance. <br /> Storage shall be maintained 2 ft (610 mm) or more from the ceiling in nonsprinklered areas of buildings. <br /> Comment: Both sales floor and storage room apply. <br /> 6 Ref. Number: NFPA 1 (2006) Florida Fire Prevention (2007) 11.1.3 Electrical Fire Safety. <br /> Permanent wiring shall be installed and maintained in accordance with NFPA 70. <br /> Comment: All areas where there is exposed electrical high voltage wiring must be inclosed in an approved raceway. If dead, wiring must be <br /> tagged "Abandoned in Place" <br /> 7 Ref. Number: NFPA 1 (2006) Florida Fire Prevention (2007) 11.1.5 Electrical Fire Safety. <br /> Extension cords shall not be used as a substitute for permanent wiring. <br /> 8 Ref. Number: NFPA 1 (2006) Florida Fire Prevention (2007) 11.1.5.2.3 Relocatable Power Taps. <br /> Relocatable power tap cords shall not extend through walls, ceilings, or floors; under doors or floor coverings; or be subject to environmental or physical <br /> damage. <br /> Comment: This pertains to extension cords. Remember extension cords are for temporary use. <br /> 9 Ref. Number: NFPA 1 (2006) Florida Fire Prevention (2007) 14.14.4* Power Source. <br /> Where emergency lighting facilities are required by the applicable provisions of Chapter 11 through Chapter 42 of NFPA 101 for individual occupancies, <br /> the signs, other than approved self - luminous signs and listed photoluminescent signs in accordance with 14.14.6.4.2, shall be illuminated by the <br /> emergency lighting facilities. The level of illumination of the signs shall be in accordance with 14.14.6.3 for the required emergency lighting duration as <br /> specified in 14.14.6.4. However, the level of illumination shall be permitted to decline to 60 percent at the end of the emergency lighting duration. <br /> [101:7.10.4] <br /> Comment: Remove exit/emergency light located at the rear door and install at street exit. <br /> Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.