Laserfiche WebLink
Zephyrhills Fire Rescue <br /> 6907 Dairy Road, Zephyrhills, FL 33542 <br /> Fire Marshal Bus (813) 780 -0041 <br /> Kerry Barnett Fax (813) 780 -0044 <br /> E -mail: kbarnett@fire.zephyrhills.fl.us <br /> Plan Review #: 10 -036 <br /> Project: Interior Renovation <br /> Number of Pages: 4 <br /> April 21, 2010 <br /> I have received and reviewed the plan for the renovation located at 38424 5 Ave and <br /> have rejected it due to the comments listed below. Should anyone have any questions, <br /> please do not hesitate to contact the Fire Marshal's office. There has been no fees <br /> assessed at this time and fees will be assessed upon an approved review. <br /> 1. A floor plan is needed to show overall layout and location of issues being <br /> corrected. <br /> 2. Opening in wall that is being closed in needs better detail. UL number listed <br /> on the attached sheet providing ratings shows 2 X 4 studs not 2 X 6 studs. It <br /> also shows 5/8" Type "X" on both sides but that is not shown on the detail. <br /> 3. Provide UL details of # 1479 and 2079 mentioned on drawn plan for <br /> penetrations. <br /> 4. There is no mention of the loft. This needs to be calculated for load capacity <br /> per square foot to ensure it meets specifications. As it is constructed now the <br /> head height is below the requirement and the stairs do not meet code. It is <br /> recommended to just remove the loft. <br /> 5. Rear egress door swings in and should swing out. It should have an approved <br /> lock installed. <br /> 6. On electric issues provide a scope of work of what is being corrected. It shall <br /> be shown on the plan. <br /> 7. Ensure w h the changes there is proper emergency /exit lighting. <br /> 1 %s� <br /> KERRY : ' ET , FIRE MARSHAL <br /> ** *Please be advised this review of plans submitted is a cursory review to assist the contractor in <br /> compliance with applicable fire safety codes. This review is not intended to be a final approval of the <br /> submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance <br /> with all applicable NFPA codes and local ordinances. In the event that further examination or site <br /> inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole <br /> expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure <br /> to be in compliance with all applicable NFPA codes and local ordinances. <br />