Laserfiche WebLink
Project No. T137.03 Page 5 of 6 <br /> GORELL "G5305" DOW:3LE RUNG WINDOW <br /> Test Results <br /> Par-a2r*0h Tekt Tide / Test Results Allowable <br /> Aderepeed Test Method <br /> GepwesePetfortnance Requirements <br /> 2.1.2 Air' Infdtration Test <br /> (ASTM E-283-91) <br /> @ 1.57 psf 0.09 cfmisf 0.30 cfm/sf <br /> The test specimen meets the performance levels specified m <br /> AAMAINTVWDA 101 1.S.2-97 for Air Infiltration. <br /> 2.1.3 Water Resistance Test <br /> (ASTM E547-96) <br /> @ 2.86 psf (w & wo screen) No penetration No penetration <br /> 2.1.4.2 Uniform Load Structural Test <br /> (see optional performance results) <br /> 2.1.7 Welded Corner Test Meets As Stated <br /> 2.1.8 Forced .Entry Resistance <br /> (ASTM F588-97) Performance <br /> Level 10 Type A (Section 10) <br /> Sec. 10.1 Lock Manipulation Test No Failure As Stated <br /> Sec. 10.2.1.1 Test Al No Failure As Stated <br /> Sec. 10.2.1.2 Test A2 No Failure As Stated <br /> Sec. 10.2.1.3 Test A3 No Failure As Stated <br /> Sec. 10.2.1.4 Test A4 No Failure As Stated <br /> Sec. 10.2.1.5 Test A5 No Failure As Stated <br /> Sec. 10.2.1.6 Test A6 No Failure As Stated <br /> Sec. 10.2.1.7 Test A7 No Failure As Stated <br /> Sec. 10.2.1.8 Lock Manipulation No Failure As Stated <br /> Test <br /> Specific Window Performance Results <br /> 2.2.1.6.1 Operating Force Test <br /> top sash 30 Ib up. 11 lb dn 30 lb <br /> bottom sash 28 lb up, 8 Ib dn 30 lb <br />