Laserfiche WebLink
ADMINISTRATION <br /> 105.3.1.1 If a state university, state community college or office has a single 3 -ton package air conditioning heat <br /> public school district elects to use a local government's code pump. The six heat pumps are connected to a single <br /> enforcement offices, fees charged by counties and munici- water cooling tower. The cost of the entire heating, venti- <br /> palities for enforcement of the Florida Building Code on lation and air - conditioning work is $47,000 and the <br /> buildings, structures, and facilities of state universities, office building accommodates fewer than 100 persons. <br /> state colleges and public school districts shall not be more Because the six mechanical units are connected to a com- <br /> than the actual labor and administrative costs incurred for mon water tower this is considered to be an 18 -ton sys- <br /> plans review and inspections to ensure compliance with the tem. It therefore could not be designed by a mechanical <br /> code. or air conditioning contractor. <br /> 1053.1.2 No permit may be issued for any building con NOTE: It was further clarified by the Commission <br /> struction, erection, alteration, modification, repair or addi- that the limiting criteria of 100 persons and $50,000 <br /> tion unless the applicant for such permit provides to the apply to the building occupancy load and the cost for <br /> enforcing agency which issues the permit any of the follow- the total air - conditioning system of the building. <br /> ing documents which apply to the construction for which <br /> the permit is to be issued and which shall be prepared by or 4 Any specialized mechanical, electrical, or plumbing <br /> under the direction of an engineer registered under Chapter document for any new building or addition which <br /> 471, Florida Statutes: includes a medical gas, oxygen, steam, vacuum, toxic <br /> air filtration, halon, or fire detection and alarm sys- <br /> 1 Plumbing documents for any new building or addi- tem which costs more than $5,000. <br /> tion which requires a plumbing system with more <br /> than 250 fixture units or which costs more than Documents requiring an engineer seal by this part <br /> q S, $50,000. shall not be valid unless a professional engineer who <br /> or possesses a valid certificate of registration has signed, <br /> V 2. Fire sprinkler documents for any new building <br /> addition which includes a fire sprinkler system which Section 471.025, Florida Statutes. <br /> contains 50 or more sprinkler heads. A Contractor 1, dated, and stamped such document as provided in <br /> Contractor II or Contractor IV, certified under Sec- 1053.2 Time limitation of application. An application for <br /> tion 633.521, Florida Statutes, may design a fire a permit for any proposed work shall be deemed to have <br /> l sprinkler system of 49 or fewer heads and may design been abandoned 180 days after the date of filing, unless <br /> such application has been pursued in good faith or a permit <br /> the alteration of an existing fire sprinkler system if the <br /> alteration consists of the relocation, addition or dele- has been issued; except that the building official is autho- <br /> tion of not more than 49 heads, notwithstanding the rized to grant one or more extensions of time for additional <br /> size of the existing fire sprinkler system. periods not exceeding 90 days each. The extension shall be <br /> 3. Heating, ventilation and air - conditioning documents requested in writing and justifiable cause demonstrated. <br /> for any new building or addition which requires more 105.33 An enforcing authority may not issue a building <br /> than a 15- ton -per- system capacity which is designed permit for any building construction, erection, alteration, <br /> to accommodate 100 or more persons or for which the modification, repair or addition unless the permit either <br /> system costs more than $50,000. This paragraph does includes on its face or there is attached to the permit the fol- <br /> not include any document for the replacement or lowing statement: "NOTICE: In addition to the require - <br /> repair of an existing system in which the work does ments of this permit, there may be additional restrictions <br /> not require altering a structural part of the building or applicable to this property that may be found in the public <br /> for work on a residential one -, two -, three or records of this county, and there may be additional permits <br /> four - family structure. required from other governmental entities such as water <br /> / management districts, state agencies or federal agencies." <br /> An air- conditioning system may be designed by an <br /> installing air - conditioning contractor certified under it ! 5.3.4 A building permit for a single - family residential <br /> Chapter 489, Florida Statutes, to serve any building or /% IF dwelling must be issued within 30 working days of applica- <br /> addition which is designed to accommodate fewer tha r 7 tion therefor unless unusual circumstances require a longer <br /> 100 persons and requires an air - conditioning system time for processing the application or unless the permit <br /> with a value of $50,000 or less; and when a 15- ton -per application fails to satisfy the Florida Building Code or the <br /> system or less is designed for a singular space of a build- enforcing agency's laws or ordinances. <br /> ing and each 15 -ton system or less has an independent <br /> duct system. Systems not complying with the above 105.3.5 Identification of minimum premium policy. <br /> Except as otherwise provided in Chapter 440, Florida Stat- <br /> require design documents that are to be sealed by a pro- utes, Workers' Compensation, every employer shall, as a <br /> fessional engineer. condition to receiving a building g permit, show proof that it <br /> Example 1: When a space has two 10 -ton systems with has secured compensation for its employees as provided in <br /> each having an independent duct system, the contractor Section 440.10 and 440.38, Florida Statutes. <br /> may design these two systems since each unit (system) is g 105.3.6 Asbestos removal. Moving, removal or disposal of <br /> less than 15 tons. <br /> asbestos - containing materials on a residential building <br /> Example 2: Consider a small single -story office build- where the owner occupies the building, the building is not <br /> ing which consists of six individual offices where each for sale or lease, and the work is performed according to the <br /> 2007 FLORIDA BUILDING CODE — BUILDING 5 +, 5 t4 f i e sic3. 7'1 1 * ) <br />