My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10591
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10591
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/2/2011 3:50:44 PM
Creation date
2/2/2011 3:50:41 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
10-10591
Building Department - Name
BARTON,WILLIAM
Address
6135 20TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> i <br /> Lab. Number 458 I <br /> April 8, 2005 <br /> Report Number 19 <br /> File Number 05 -116 <br /> Page 2 of 4 <br /> D-7007 <br /> MATERIAL CHARACTERISTICS <br /> Hardware: (continued) <br /> Quantity Description Location <br /> Two surface mount metallic keeper, with no I.D. marks one at fixed meeting rail, 7" from each end <br /> Two 33 3/4" long vinyl balance cover, with no I. D. marks one at each frame jamb <br /> Two nylon block shoe clip, with no 1.D. marks one at each frame jamb <br /> Two 2 5/8" long vinyl vent stop, with no 1.D. marks at each upper frame jamb <br /> Two - metallic ivot bar, with no I.D. marks one at each � h end of vent bottom rail <br /> Weepboles: <br /> Quantity Description Location <br /> Four 1" by 1/4" weep hole with plastic baffles at flame sill flange 3 %3 ", 5 ", 48 ''A" and 49 3/4" <br /> Four 3/8" by 1/8" weep slot at frame sill, 3 and 49 5/8" from left <br /> Two 1" by 1/8" weep slot at frame sill, 3 3/4" and 49 3/8" from Left <br /> Mooting: None <br /> Mullions: None <br /> Reinforcement: One 33 3/4" long al i minum reinforcement, drawing No. 5114, inside vent jamb rail,(total of two). One <br /> 48" long aluminum reinforcement, drawing No.5103, inside fixed meeting rail. One 45 3/4" long aluminum <br /> reinforcement, drawing No. 5114, inside vent top and bottom rail, (total of two). One '/2" by 1/16" by 1 '/" long <br /> aluminum plate, drawing No. 5115, at each end of fixed meeting rail fastened with the same size and type of assembly <br /> scrcws. <br /> Sealants: Fixed meeting rail at each end were sealed with a clear colored seam sealer. <br /> Pads: None <br /> Screen: Water resistance test conducted with and without a fiberglass mesh screen installed. <br /> Additional Description: The metallic pivot bars were fastened with two No. 6 by 1" flat head self drilling screws. <br /> Unit Installation: Test unit installed in a 2 x 12 pressure treated wood test buck with a 2 x 4 pressure treated buck strip. <br /> Frame installed with a single row of 10 by 2" pan head sheet metal screws at frame head and frame jambs. Location of <br /> installation screws are as follows: frame head from the left, 6 5/8 ", 26 5/8 and 46 5/8 "; frame jambs from the bottom, <br /> 6 5/8 ", 20 %: ", 34 1/8 ", 44 1/8 ", 54 7/8" and 65 5/8 ". There were no installation screws in frame sill. <br /> Product Markings: None <br /> OFFICIAL TEST RESULTS <br /> Paragraph Number Title of Test Measured Allowed <br /> 2.1.2 Air Infiltration Test: (ASTM E283 -96) Passed <br /> at 1.57 psf 0.11cfin/sq.ft. (1.87 cmh/m 0.3 (5.49) maximum <br /> Note: The tested specimen meets or exceeds the performance levels specified in specification reference <br /> for air infiltration. <br /> 2.1.3 Water Resistance Test: (ASTM E547- 96/E331) Passed <br /> with and without screen, no leakage at 9.00 psf (431 Pa) 2.86 (137) minimum <br /> // <br />
The URL can be used to link to this page
Your browser does not support the video tag.