My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10679
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10679
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2011 11:17:54 AM
Creation date
2/3/2011 11:17:50 AM
Metadata
Fields
Template:
Building Department
Company Name
CRESTVIEW HILLS
Building Department - Doc Type
Permit
Permit #
10-10679
Building Department - Name
DOMALIK,NEIL & HEATHER
Address
7918 MERCHANTVILLE CIR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Architectural Testing <br /> AAMAIWDMA/CSA 101/I.S.2/A440 05 <br /> TEST REPORT <br /> Rendered to: <br /> GORELL ENTERPRISE, INC. <br /> SERIES/MODEL: 6302 / 6352 / 6402 <br /> PRODUCT TYPE: PVC Sliding Glass Door, Type OX <br /> It- Summary of Results <br /> Title Test Specimen #1 Test Specimen #2 with Test Specimen #3 <br /> Model 6302 aluminum with steel <br /> reinforcement reinforcement <br /> Model 6352 Model 6402 <br /> Primary Product Designator SD-R35 1797 x 2019 SD -R50 I797 x 2019 SD -R50 1797 x 2019 <br /> (71 x 80) (71 x 80) (71 x 80) <br /> Design Pressure * *±1680 Pa (+35.11 psf) * *±2400 Pa (+50.16 psf) ±2400 Pa (+50.16 psf) <br /> Operating Force (in motion) ** 45 N (I0 Ibt) N/A N/A <br /> Air Infiltration ** L I 1 L/s /m N/A <br /> (4.22 cffn/tt`') N/A <br /> Water Penetration Resistance ** 360 Pa (732 psf) N/A N/A <br /> Test Pressure <br /> Uniform l- Pressureetural Test * *± 520Pa (+52.66 psf) * *±3600 Pa (+75.24 psf) +3600 Pa (+75.24 psf <br /> I Forced Entry Resistance * *Grade 10 N/A N/A <br /> Test Completion Date: 09/12/08 <br /> This report contains in Its entirety: `�o''' ` Qi��, <br /> iet <br /> Cover Page: I page RF �. <br /> Report Body: 10 pages <br /> Drawings: 20 pages -- ° ssa�s = <br /> -23 STATE OF =- <br /> 2008.09.12 16:28:42 - 04'00' <br /> Reference must be made to Report No. 83040.02- 501 -44, dated 09/12/08 for complete test <br /> specimen description and data. Reference Architectural Testing, Inc. Report No. <br /> 83040.01- 501 -44, dated 05/28/08 for these test ( * *) results. <br /> 1140 Lincoln Avenue <br /> Springdale, PA 15144 <br /> phone: 724 -275 -7100 <br /> fax: 724- 275 -7102 <br /> www.archtest.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.