• <br /> Deck Type 1I: Wood, Insulated <br /> Deck Description: 19 /32" or greater plywood or wood plank <br /> System Type D: All layers of insulation and base sheet simultaneously attached. <br /> All General and System Limitations apply. <br /> Insulation Layer Insulation Fasteners Fastener <br /> (Table 3) Density /ft <br /> AC FOAM II, AC FOAM III, , Pyroz, E'NRG'Y III, PSI -25, UltraGard Gold, UltraGard Premier, <br /> Firestone ISO-95 GW, ES Foam I, Hunter Panel, High Density Wood Fiber, Extruded or <br /> Expanded Polystyrene <br /> Minimum 1Y2" thick N/A N/A <br /> Note: Insulation layer shall be mechanically attached with fasteners and density described above. <br /> Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of <br /> fasteners per board shall be increased maintaining the same fastener density (See Roofing <br /> Application Standard RAS 117 for fastening details). <br /> Membrane with 25" tabs: Duro-Last membrane shall be mechanically attached at its 6" wide tabs, <br /> spaced every 25" o.c. with Duro -Last #15 EHD Screws with Duro-Last Cleat <br /> Plates or ITW Buildex 2 -3/8" Eyehook Plates spaced 6" o.c. maximum, <br /> through the insulation and into the deck. Duro-Last Tab Sealant 4725 shall <br /> be applied over the tab membrane and to the overlying membrane underside <br /> at a rate of 60 ft2/gal (two-sided application). <br /> (Maximum Design Pressure - 97.5 psf,• See General Limitation #7) <br /> Membrane with 57" tabs: Duro-Last membrane shall be mechanically attached at its 6" wide tabs, <br /> spaced every 57" o.c. with Duro-Last HD Screws ( #14) with Duro-Last 3- <br /> inch Metal Plates spaced 6" o.c. maximum, through the insulation and into <br /> the deck. Duro-Last Tab Sealant 4725 shall be applied over the tab <br /> membrane and to the overlying membrane underside at a rate of 60 ft2 /gal <br /> (two-sided application). <br /> (Maximum Design Pressure - 52.5 psf, See General Limitation #7) <br /> Duro-Last membrane shall be mechanically attached at its 6" wide tabs, <br /> spaced every 57" o.c. with Duro -Last EHD Screws ( #15) with Duro-Last <br /> Cleat Plates or ITW Buildex 2 -3/8" Eyehook Plates spaced 6" o.c. <br /> maximum, through the insulation and into the deck. Fastener -line located <br /> 2.7 -inch from tab edge. <br /> (Maximum Design Pressure - 52.5 psj; See General Limitation #7) <br /> Membrane with 60" tabs: Duro-Last membrane shall be mechanically attached at its 3" wide tabs, <br /> spaced every 60" o.c_ with Duro -Last HD Screws (#14) with Duro -Last Poly <br /> Plates spaced 6" o.c. maximum, through the insulation and into the deck. <br /> Duro-Last Tab Sealant 4725 shall be applied over the tab membrane and to <br /> the overlying membrane underside at a rate of 60 ft2/gal (two -sided <br /> application). <br /> (Maximum Design Pressure - 45.0 psf; See General Limitation #77 <br /> Maximum Design See fastening above <br /> Pressure: <br /> NOA No.: 07- 1018.14 <br /> t;1 :1•, _, 1�1i�.: .� Expiration Date: 08/22/12 <br /> APPRCdEJ. Approval Date: 02/21/08 <br /> Page 8 of 10 <br />