My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10680
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10680
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2011 11:19:56 AM
Creation date
2/3/2011 11:19:53 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
10-10680
Building Department - Name
JOHNSON,DEAN
Address
5930 8TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> WOOD DECK SYSTEM LIMITATIONS: <br /> 4 <br /> I. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor <br /> sheet. <br /> GENERAL LIMITATIONS: <br /> 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials <br /> Directory for fire ratings of this product. <br /> 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with <br /> Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved <br /> asphalt applied within the EVT range and at a rate of 20-40 lbs.sq., or mechanically attached using <br /> the fastening pattern of the top layer <br /> 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved <br /> asphalt, panel size shall be 4' x 4' maximum. <br /> 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell <br /> foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet <br /> shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip <br /> mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a <br /> continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed <br /> every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a <br /> minimum rate of 12 lbs.sq. <br /> Note: Spot attached systems shall be limited to a maximum design pressure of - 45 psf. <br /> 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of <br /> 275 1b£, as tested in compliance with Testing Application Standard TAS 105. If the fastener value, <br /> as field - tested, are below 275 Ib£ insulation attachment shall not be acceptable. <br /> 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based <br /> on a minimum fastener resistance value in conjunction with the maximum design value listed within <br /> a specific system. Should the fastener resistance be less than that required, as determined by the <br /> Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered <br /> Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing <br /> shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and <br /> calculations in compliance with Roofing Application Standard RAS 117. <br /> 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these <br /> areas. Fastener densities shall be increased for both insulation and base sheet as calculated in <br /> compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed <br /> by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant <br /> (When this limitation is specifically referred within this NOA, General Limitation #9 will not be <br /> applicable.) <br /> 8. All attachment and sizing of perimeter milers, metal profile, and/or flashing termination designs shall <br /> conform with Roofing Application Standard RAS 111 and applicable wind load requirements. <br /> 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. <br /> field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for <br /> enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). <br /> (When this limitation is specifically referred within this NOA, General Limitation #7 will not be <br /> applicable.) <br /> END OF THIS ACCEPTANCE <br /> NOA No.: 07- 1018.14 <br /> Expiration Date: 08/22/12 <br /> AFFP.O.'EL Approval Date: 02/21/08 <br /> Page 10 of 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.