Laserfiche WebLink
EnCon Services, Inc. <br /> Sign Design Calculations <br /> Job Description PREPARED BY: EnCon Services, Inc. <br /> Medical Group of Tampa Bay 2272 Jaudon Road <br /> 38011 Arbor Ridge Dr. Dover, FL 33527 <br /> Zephyrhills, Florida 813 - 655 -3373 <br /> 2'- 9 -1/2" Logo F 813 - 655 -9814 <br /> Design per 2007 Florida Building Code, 2009 supplement, Section 16 Wind Load <br /> ASCE 7 -05 Aaron Biedenbach, P.E. <br /> Design Specifications <br /> 1 FL PE #52949, FL EB 9394 <br /> Importance Factor 1 OH PE 60756, OC #01893 <br /> Kzt 1 KY PE #20281, P #2463 <br /> Exposure Factor B IN PE #PE 19600322 <br /> Kd 1 FL CBC #060535, QB #22527 <br /> Kz 0.7 <br /> V 120 mph <br /> GCp -GCpi 1.28 Zone 4, h < 60 <br /> Wind Pressure 33.0 (psf) <br /> Sign Information <br /> Height 2.79 (ft) <br /> Width 2.79 (ft) <br /> Area 6.12 ( ) f f <br /> Thickness 0.17 (ft) ,, , 1 f BI E p <br /> Distance grade to top 30 (ft) � Q. H� . <br /> ` N 0 . .. G S Se. • <br /> Wind Sheer Force 15.67 (Ib) 4t. : • ?' <br /> Weight of Sign 24 (Ib) , 1 r • No 5 2949 - _ <br /> Total Sheer Force = 29.06 (Ib) * * • F • <br /> Total Tension Force = 202.14 (Ib) A 0 .9 . • • • � C9 <br /> Required Provided °iis$/ONp►; <br /> :40 <br /> Fastener size (Nominal) 1/4 1/4 <br /> Minimum number of fasteners 6 6 <br /> Sheer Force per fastener (Ib) 4.8 65 <br /> Tension Force per fastener (Ib) 33.7 50 <br /> Combination Tension and 0.75 <1 O.K. <br /> Sheer ratio <br /> Fastener to be threaded stud epoxied into wall structure. 1 -1/2" embedment into concrete <br /> USE HILT! HY -20 OR EQUAL EPDXY ADHESIVE <br /> 7/13/2010 <br /> Medical Group of Tampa Bay Zephyrhills 2 -9 Togo <br />