My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10737
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10737
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/4/2011 3:37:04 PM
Creation date
2/4/2011 3:36:59 PM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA HOSPITAL OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
10-10737
Building Department - Name
FLORIDA HOSPITAL OF ZEPHYRHILLS
Address
7050 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> If each cell is to be equipped with an outlet, side - suctions Makeup %Mater Flow Required -GPM <br /> can be used on end cells of multicell towers, but not on to Maintain Three (3) Concentrations <br /> interior cells. For direct outlet from each cell on installations Tower Cooling "Range" (hot water minus cold water) <br /> of three or more cells, use either the depressed sump or GPM 5" F 10" F 15 F 20° F 30° F 40° F <br /> bottom outlet on interior cells. 200 2 3 4 5 8 10 <br /> The best choice for a tower used with a remote or indoor 400 3 5 8 10 15 20 <br /> 600 <br /> storage tank —see page 20 —or on a concrete cold water 800 4 8 12 15 23 30 <br /> basin is usually a bottom outlet. <br /> 800 5 10 15 20 30 40 <br /> 1,000 7 13 19 25 38 50 <br /> A side - suction equipped tower can be installed on a flat 1,soo 10 19 29 38 57 75 <br /> concrete slab if a side drain and overflow are also speci- 2,000 13 25 38 50 75 100 <br /> fied —see page 16. Consult your Marley sales engineer for 3,000 19 38 57 75 113 150 <br /> complete information. 4,000 25 50 75 100 150 200 <br /> 5,000 32 63 94 125 188 250 <br /> ,000 38 `` -75 1 150 225 300 <br /> Makeup ✓` 8,000 50 100 150 200 300 400 <br /> The amount of water constantly evaporated from a NOTE <br /> cooling tower varies directly with the heat load applied. In If circulating water is to be maintained at 2 concentrations instead of <br /> addition to evaporation, water is normally lost to the blow- 3, multiply table GPM values by 1.36 before sizing makeup valve. <br /> down (bleed -off) necessary to maintain dissolved solids <br /> concentration at an acceptable level in the circulating water <br /> system. <br /> The NC is equipped with one or more float- operated, <br /> mechanical makeup valves to automatically replenish this Makeup Valve Flow Capacities-GPM <br /> lost water. The tables on this page, calculated for a concen- Pressure at Valve Inlet 1" Diameter 2" Diameter <br /> tration of 3 times normal, indicate the rate of water loss—and while flowing-psig Valve Valve <br /> the size ofvalve(s) required. If your installation's cold water 10 56 90 <br /> basin will drain by gravity to a remote storage tank —or if <br /> you plan a separate means of controlling makeup water— 20 78 120 <br /> a price reduction is available fordeleting the Marley- supplied 30 92 143 <br /> valve(s). Marley also offers an optional electronic liquid - 40 106 160 <br /> level contol. <br /> 50 117 167 <br /> 77 NOTE <br /> �/ • If makeup water pressure exceeds 50 psig, use pressure reduc=r <br /> ahead of valve. ) <br /> • For flow requirements exceeding the above limitations, use / <br /> \ multiples of the same size valve. <br /> 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.