My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10833
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10833
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2011 10:53:30 AM
Creation date
2/7/2011 10:53:27 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
10-10833
Building Department - Name
KNIGHT,RANDOLPH
Address
38022 MEDICAL CENTER AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Zephyrhills Fire Rescue <br /> 6907 Dairy Road, Zephyrhills, FL 33542 <br /> Fire Marshal Bus (813) 780 -0041 <br /> Kerry Barnett Fax (813) 780 -0044 <br /> E -mail: kbarnet0fire.zephyrhills.fl.us <br /> Plan Review #: 10 -092 <br /> Project: Reconstruction of Space <br /> Number of Pages: 14 <br /> August 11, 2010 <br /> I have received and reviewed the plans for the reconstruction of a medical space located at 38022 <br /> Medical Center Ave and will allow the plans to move forward. This project is considered as <br /> building reconstruction per NFPA 101, 43.5.2.1. The reviewing chapters used are Chapter 38 & <br /> 39 pending the guidance of 43. Any referencing chapter were also utilized for this review. By <br /> paying for permit contractor acknowledges to comply with the items below. Should anyone have <br /> any questions, please do not hesitate to contact the Fire Marshal's office. <br /> 1. The plans received indicate a fire alarm system. Installing contractor shall submit <br /> separate plans to obtain a permit to perform the job. All cut sheets /details of devices <br /> used along with battery calcs shall be submitted. <br /> 2. Any penetration to the fire wall will require an approved listed method to maintain <br /> that rating. The method used shall be provided to this authority to ensure the rating <br /> is maintained. <br /> 3. Ensure the secondary egress (door) has a single motion to get out. No dead bolts or <br /> secondary locks. <br /> 4. The calculated cfm's are over 2000 therefore install a duct detector for the air <br /> handler unit per 6.4.2.1 of NFPA 90A. Duct detector shall also be tied into fire <br /> alarm system and shut down the unit per 6.4.4.2 of NFPA 90A. <br /> 5. Building appears to have a lightweight truss system. Per FAC 69A- 60.008 a <br /> lightweight truss sign shall be installed at the main door, left side at a height of 4 - 6 <br /> ft. <br /> Inspection Required <br /> 1. Penetration Inspection <br /> 2. Final <br /> KERRY BARNETT, FIRE MARSHAL <br /> ** *Please be advised this review of plans submitted is a cursory review to assist the contractor in <br /> compliance with applicable fire safety codes. This review is not intended to be a final approval of the <br /> submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance <br /> with all applicable NFPA codes and local ordinances. In the event that further examination or site <br /> inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole <br /> expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure <br /> to be in compliance with all applicable NFPA codes and local ordinances. <br />
The URL can be used to link to this page
Your browser does not support the video tag.