Laserfiche WebLink
FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1531 MARTINQUE 214 D Builder Name: LENNAR <br /> Street Permit Office: <br /> City, State, Zip: TAMPA , FL , Permit Number. <br /> Owner: LENNAR HOMES Jurisdiction: <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area <br /> a. Concrete Block - Int Insul, Exterior R =4.1 541.33 ft' <br /> 2. Single family or multiple family Multi- family <br /> b. WA R= ft" <br /> 3. Number of units, if multiple family 1 c. N/A R= ft: <br /> 4. Number of Bedrooms 2 d. N/A R= ft' <br /> 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area <br /> 6. Conditioned floor area (ft') 1531 a. Under Attic (Vented) R =30.0 766.00 ft <br /> b. N/A R= ft' <br /> 7. Windows Description Area c. N/A R= ft2 <br /> a. U- Factor: Dbl, U =0.60 100.98 ft' <br /> SHGC: SHGC =0.32 11. Ducts <br /> b. U- Factor. Sgl, U =1.17 40.00 ft' a. Sup: Attic Ret Attic AH: Interior Sup. R= 6, 355 ft' <br /> SHGC: SHGC =0.74 12. Cooling systems <br /> c. U- Factor: N/A ft' a. Central Unit Cap: 34 kBtu/hr <br /> SHGC: SEER: 14 <br /> d. U- Factor: N/A ft' <br /> 13. Heating systems <br /> SHGC: <br /> a. Electric Heat Pump <br /> e. U- Factor: N/A ft' Cap: 34 kBtu/hr <br /> SHGC: HSPF: 8.2 <br /> 14. Hot water systems <br /> 8. Floor Types Insulation Area a. Electric <br /> a. Slab -On -Grade Edge Insulation R =0.0 1531.00 ft' Cap: 40 gallons <br /> b. Raised Floor R =19.0 88.00 ft' EF: 0.92 <br /> b. Conservation features <br /> c. N/A R= ft' <br /> None <br /> 15. Credits Pstat <br /> Glass /Floor Area: 0.092 Total As Built Modified Loads: 30.94 PASS <br /> Total Baseline Loads: 38.54 <br /> 1 hereby certify that the plans and specifications covered by Review of the plans and .. i1iE 8T ,.. <br /> ov ......Ali'' <br /> this calculation are in compliance with the Florida Energy specifications covered by this , N. .. i , .2 . O <br /> Code. calculation indicates compliance . c ,,, • ` . _ ,„6 : <br /> . : .. <br /> P.,....kii with the Florida Energy Code. 3 E.` rr,,, '4, ` PREPARED BY: - Before construction is completed - a `' ry • • ti 6_ . <br /> DATE: this building will be inspected for C l ��i a <br /> 1 compliance with Section 553.908 <br /> I hereby certify that this building, as designe• A�i! •m• ce Florida Statutes. •'. * f' V'`" ' . ; * ;� <br /> with the Florida Energy Code. ! C <br /> OWNER/AGENT: /AM <br /> DUI LDING OFFICl/,;� _ // OD <br /> � i <br /> DATE: �t� DATE: <br /> 1 <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory- sealed in accordance with N1110.A.3. <br /> 3/24/2009 2:51 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5 <br />