Laserfiche WebLink
FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1531 MARTINQUE 214 0 Builder Name: LENNAR <br /> Street Permit Office: <br /> City, State, Zip: TAMPA , FL , Permit Number: <br /> Owner. LENNAR HOMES Jurisdiction: <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area <br /> 2. Single family or multiple family Multi - family a. Concrete Block - Int Insul, Exterior R=4.1 541.33 ft <br /> b. N/A R= ft <br /> 3. Number of units, if multiple family 1 c. WA R= ft <br /> 4. Number of Bedrooms 2 d. N/A R= ft <br /> 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area <br /> 6. Conditioned floor area (ft 1531 a. Under Attic (Vented) R =30.0 766.00 ft <br /> b. N/A R= ft <br /> 7. Windows Description Area c. N/A R= ft <br /> a. U- Factor: Dbl, U =0.60 100.98 ft <br /> SHGC: SHGC =0.32 11• Ducts <br /> b. U- Factor: Sgl, U =1.17 40.00 ft' a. Sup: Attic Ret Attic AH: Interior Sup. R= 6, 355 ft <br /> SHGC: SHGC =0.74 12. Cooling systems <br /> c. U- Factor: N/A ft a. Central Unit Cap: 34 kBtu/hr <br /> SHGC: SEER: 14 <br /> d. U- Factor: N/A ft' 13. Heating systems <br /> SHGC: a. Electric Heat Pump Cap: 34 kBtu/hr <br /> e. U- Factor. N/A 52 <br /> HSPF: 8.2 <br /> SHGC: <br /> 14. Hot water systems <br /> 8. Floor Types Insulation Area a. Electric Cap: 40 gallons <br /> a. Slab -On -Grade Edge Insulation R =0.0 1531.00 ft2 EF: 0.92 <br /> b. Raised Floor R =19.0 88.00 ft2 b. Conservation features <br /> c. N/A R= ft' None <br /> 15. Credits Pstat <br /> Glass /Floor Area: 0.092 Total As Built Modified Loads: 30.94 PASS <br /> Total Baseline Loads: 38.54 • I hereby certify that the plans and specifications covered by Review of the plans and ' .•.04THE S7 I .,. <br /> this calculation are in compliance with the Florida Energy specifications covered by this �.: ', : <br /> Code. calculation indicates compliance 1.47; , c• • <br /> , <br /> with the Florida Energy Code. - ' „ 44 .. , ;. 1 , " ?. .;. " �p <br /> PREPARED BY: : <br /> � 0 � Before c onstruction is completed • r� � • _ �.=.; � ®; i~ E <br /> DATE: this building will be inspected for . ., 1 �1I K'"°'" a <br /> compliance with Section 553.908 *' , <br /> I hereby certify that this building, as design./ ' .nce Florida Statutes. r <br /> �.- . � C o D . ‘p..... OWNER/AGENT: ; % . i/I �� <br /> with the Florida Energy Code. I( ............... <br /> � - � / B UILDING OFFI �_- <br /> DATE: Ltd. • �� % DATE: (J <br /> Q � <br /> - Compliance requires certification • y the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory- sealed in accordance with N1110.A.3. <br /> 3/24/2009 2:51 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5 <br />