My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10880
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10880
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2011 1:39:16 PM
Creation date
2/7/2011 1:39:12 PM
Metadata
Fields
Template:
Building Department
Company Name
GRAND HORIZONS
Building Department - Doc Type
Permit
Permit #
10-10880
Building Department - Name
CLARK,JOSEPH & MARGARET
Address
37630 GILL AVE LOT 266
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R W R W Building Consultants, Inc. <br /> 13 Consulting and Engineering Services for the Building Industry <br /> P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Facsimile 813.754.9989 <br /> Florida Board of Professional Engineers Certificate orAuthoriration No. 9813 <br /> Product Evaluation Report Report No.: FL 8134.1 R3 <br /> Date: August 24, 21109 <br /> Product Sub Category Manufacturer <br /> Category Product Name <br /> Window Double Hung ,Aside Window Company Model 0201 <br /> 3773 State Road Extruded Vinyl <br /> Cuyahoga Falls, 011 44223 Double Hung Window <br /> Phone 330.922,2108 "Non- Impact" <br /> Scope: Product Evaluation report issued by R W Building Consultants, Inc. & Lyndon F. Schmidt, P.E. (System ID # 1998) for <br /> Aiside Window Company, based on Rule Chapter No. 9B- 72.070, Method 1A of the State of Florida Product Approval, Dept. of <br /> Community Affairs - Florida Building Commission. <br /> RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest In the company manufacturing <br /> or distributing the product or in any other entity involved in the approval process of the product named herein. <br /> Limitations: <br /> 1. This product has been evaluated and is in compliance with the 2007 Florida Building Code structural requirements excluding the "High Velocity <br /> Hurricane Zone ". <br /> 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. <br /> 3. When used in areas requiring wind borne debris protection, this product is required to be protected with an impact resistant covering that complies <br /> with Section 1609.1.2 of the Florida Building Code. <br /> 4. Site conditions that deviate from the details of drawing FL- 8134.1 require further engineering analysis by a licensed engineer or registered architect. <br /> 5. For 2X stud construction, anchoring of the assemblies shall be as shown for 2X buck masonry construction. <br /> 6. See drawing FL- 8134.1 for size and design pressure limitations <br /> Supporting Documents: <br /> 1. Test Report No. Test Standard Testing Laboratory Signed by <br /> ATI 62508.02- 501 -47 AAMA/WDMA/CSA 101/I.S.2/A440 -05 Architectural Testing, Inc. Michael L, Mackereth <br /> ATI 62609.02- 501 -47 AAMAMWDMA /CSA 101/I.S.2/A440 -05 Architectural Testing, Inc. Michael L. Mackereth <br /> 2. Drawing No. Prepared by <br /> No. FL- 8134.1 RW Building Consultants, Inc. (CA #9813) Signed & Sealed by <br /> Lyndon F. Schmidt, P.E. <br /> 3. Calculations Prepared by <br /> Buck Anchoring RW Building Consultants, Inc. (CA #9813) Signed & Sealed by <br /> Lyndon F. Schmidt, P.E. <br /> 4. Quality Assurance <br /> Certificate of Participation issued by Architectural Testing, Inc., certifying that Aiside Window Company <br /> is manufacturing products within a quality assurance program that complies with ISO /IEC 17020 and Guide 53. <br /> PF 1273 Lyndon F. Schmidt, P.E. <br /> Sheet 1 of 1 FL PE No. 43409 <br /> 9/1/2009 <br />
The URL can be used to link to this page
Your browser does not support the video tag.