My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
09-9292
Zephyrhills
>
Building Department
>
Permits
>
2009
>
09-9292
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2011 4:01:17 PM
Creation date
3/21/2011 3:51:40 PM
Metadata
Fields
Template:
Building Department
Company Name
CITY OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
09-9292
Building Department - Name
CITY OF ZEPHYRHILLS
Address
6907 DAIRY RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 4 of 8 TFP51 O <br /> ORDER LENGTHS: Operation <br /> 2-1/2" to 48" (63,5 to 1219,2 mm) <br /> _ IN 1/4' (6,4 mm) INCREMENTS 4' i 1/8' <br /> (101,6 x 3,2 mm) When the Series DS -1 is in service, <br /> FACE OF FACE OF 1 -3/4' DIA. water is prevented from entering the <br /> — SPRINKLER MOUNTING — (44,5 mm) assembly by the Plug & Belleville Seal- <br /> __ -i L FITTING SURFACE \ ing Assembly (Ref. Figure 1) in the <br /> 1 Inlet of the Sprinkler. The glass Bulb <br /> ! � ll1!,;I dui i1 3" DIA. contains a fluid that expands when ex- <br /> i;I1 Jai I (76,2 mm) posed to heat. When the rated tem- <br /> r / 3.5° perature is reached, the fluid expands <br /> ' SPRINKLER FITTING sufficiently to shatter the glass Bulb, <br /> -' (REFER TO DESIGN CENTERLINE 5/16" and the Bulb Seat is released. The <br /> CRITERIA SECTION) OF WATERWAY (7,9 mm) compressed Spring is then able to ex- <br /> FIGURE 9 pand and push the Water Tube as well <br /> TY3335 HORIZONTAL SIDEWALL w/ STANDARD ESCUTCHEON as the Guide Tube outward. This action <br /> simultaneously pulls inward on the <br /> Yoke, withdrawing the Plug & Belleville <br /> ORDER LENGTHS: FACE OF Seal from the Inlet allowing the sprin- <br /> 1/2' to 45-3/4" (12,7 to 1162,1 mm) MOUNTING kler to activate and flow water. <br /> IN 1 /4' (6,4 mm) INCREMENTS SURFACE <br /> 4- 13/16 "± 1/8' <br /> (122,2 * 3,2 mm) <br /> FACE OF --"2-1/2" DIA. <br /> SPRINKLER (63,5 mm) <br /> -1 -i FITTING \ 1 Design <br /> " DIA. <br /> Criteria <br /> � ' �1I1I I • —I ' <br /> ii�ll hill / 3-1/2 (88,9 mm) The Series DS -1 Sprinklers are in- <br /> ,- - � 3.5° <br /> tended for use in fire sprinkler systems <br /> SPRINKLER FITTING NI designed in accordance with the <br /> -- -'--- (REFER TO DESIGN CENTERLINE 5/16' standard installation rules recognized <br /> CRITERIA SECTION) OF WATERWAY (7,9 mm) by the applicable Listing or Approval <br /> FIGURE 10 agency (e.g., UL Listing is based on <br /> TY3335 HORIZONTAL SIDEWALL w/ DEEP ESCUTCHEON NFPA 13 requirements). <br /> The Series DS -1 Dry Type Sprinkler is <br /> ORDER LENGTHS: to be installed in the 1 inch NPT outlet <br /> 5' to 48" (127,0 to1219,2mm) or run of malleable or ductile iron <br /> IN 1/4" (6,4 mm) INCREMENTS MINIMUM threaded tee fittings that meet the di- <br /> 2-1/4"(57,2mm) mensional requirements of ANSI <br /> DEFLECTOR TO <br /> ACE OF MOUNTING B16.3 (Class 150) or cast iron <br /> — SPRINKLER SURFACE threaded tee fittings that meet the di- <br /> _ 1 ( <br /> FITTING mensional requirements of ANSI <br /> B16.4 (Class 125) with the end sprin- <br /> ql, 'I ! kler fitting on a branch line to be <br /> i� � ! / Th7 plugged as shown in Figures 3 - 11. <br /> '- 3.5° 5/16" <br /> �� 79 6" When installing 1 inch NPT Series <br /> SPRINKLER FITTING (' <br /> DS -1 Dry Type Sprinklers on a dry pipe <br /> - = — ' (REFER TO DESIGN CENTERLINE sprinkler system, only use the side <br /> CRITERIA SECTION) OF WATERWAY outlet of maximum 2 -1/2 inch size re- <br /> FIGURE 11 ducing tee's. <br /> TY3335 HORIZONTAL SIDEWALL w/o ESCUTCHEON For wet pipe sprinkler systems, the <br /> Series DS -1 Dry Type Sprinklers may <br /> also be installed in the 1 inch NPT <br /> outlet of a Central Figure 730 Me- <br /> chanical Tee or the following Tyco Fire <br /> Products CPVC fittings: (P /N 80145) <br /> 1" x 1" NPT Female Adapter or (P /N <br /> 80249) 1 "x 1 "x 1" NPT Sprinkler Head <br /> Adapter Tee. <br /> NOTE <br /> Do not install the Series DS -1 into any <br /> other type fitting without first consult- <br /> ing the Technical Services Depart- <br /> ment. Failure to use the appropriate <br /> fitting may result in: failure of the sprin- <br /> kler to properly operate due to forma- <br /> tion of ice over the inlet Plug or binding <br /> of the inlet Plug; or, insufficient en- <br />
The URL can be used to link to this page
Your browser does not support the video tag.