Laserfiche WebLink
Page 2 of 6 TFP176 <br /> SPRINKLER FINISH (See Note 11) <br /> K TYPE TEMP. BULB NATURAL CHROME WHITE"** LEAD <br /> LIQUID BRASS PLATED POLYESTER COATED <br /> 135 °F /57 °C Orange <br /> HORIZ. 155 °F /68 °C Red <br /> SIDEWALL 1, 2, 3, 4, 9, 10 1, 2, 3, 9 1, 2, 3, 9 <br /> (TY3331) 175 °F /79 °C Yellow <br /> 200 °F /93 °C Green <br /> 5.6 286 °F /141 °C Blue <br /> 1/2" <br /> NPT RECESSED 135 °F /57 °C Orange <br /> HORIZ. 155 °F /68 °C Red <br /> SIDEWALL 1, 2, 4, 9, 10 1, 2, 9 N/A <br /> (TY3331)* 175 °F /79 °C Yellow <br /> Figure 3 200F/93°C Green <br /> RECESSED 135 °F /57 °C Orange <br /> HORIZ. 155 °F /68 °C Red <br /> SIDEWALL 1, 2, 3, 4, 9 N/A <br /> (TY3331) ** 175 °F /79 °C Yellow <br /> Figure 4 200 °F /93 °C Green <br /> VERTICAL 135 °F /57 °C Orange <br /> SIDEWALL 155 °F /68 °C Red <br /> 5.6 (TY3431) 5, 6, 7, 8, 9 5, 6, 7, 9 <br /> 1/2" Installed 175 °F /79 °C Yellow <br /> NPT Pendent 200 °F /93 °C Green <br /> or <br /> Upright 286 °F /141 °C Blue <br /> NOTES: <br /> 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a <br /> 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. <br /> 2. Listed by Underwriters Laboratories Inc. for use in Canada (C -UL) as Quick Response Sprinklers for use in Light and Ordinary <br /> Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. <br /> 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers for use in Light Hazard Occupancies at a <br /> 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. <br /> 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007a/04) at a 4 to 6 inch (100 to 150 mm) top of <br /> deflector to ceiling distance. The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. <br /> 5. Listed by Underwriters Laboratories, Inc. as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. <br /> 6. Listed by Underwriters Laboratories for use in Canada (C -UL) as Quick Response Sprinklers for use in Light and Ordinary Hazard <br /> Occupancies. <br /> 7. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers for use in Light Hazard Occupancies. <br /> 8. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06 & 007a/04) as Quick Response Sprinklers. <br /> 9. Approved by the City of New York under MEA 354 -01 -E. <br /> 10. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) at a 4 to 6 inch (100 to 150 mm) top of <br /> deflector to ceiling distance. The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. <br /> 11. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed <br /> as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as <br /> Corrosion Resistant Sprinklers. <br /> * Installed with Style 10 (1/2" NPT) 3/4" Total Adjustment Recessed Escutcheon. <br /> ** Installed with Style 20 (1/2" NPT) 1/2" Total Adjustment Recessed Escutcheon. <br /> * ** Frame and deflector only. Listings and approvals apply to color (Special Order). <br /> TABLE A <br /> LABORATORY LISTINGS AND APPROVALS <br /> Physical Characteristics <br /> Frame Bronze Operation <br /> Button Brass /Copper <br /> Sealing Assembly The glass Bulb contains a fluid which F- <br /> Beryllium Nickel w /Teflont expands when exposed to heat. When <br /> Bulb Glass the rated temperature is reached, the <br /> Compression Screw Bronze fluid expands sufficiently to shatter the o, <br /> HSW Deflector Bronze glass Bulb, allowing the sprinkler to <br /> VSW Deflector Copper activate and water to flow. <br /> Patents o <br /> a <br /> U.S.A. 5,810,263 7 <br />